This manual corresponds to the following references: Console included*: Console not included*: BI115TUA BI115TUQA 120 V - N. America, Taiwan 120 V - N. America, Taiwan BI115TIA BI115TIQA 230 V - India 230 V - India BI115TA BI115TQA 230 V - Europe 230 V - Europe BI115TKA BI115TKQA...
Features and Connections Stand for B 115T Nano B·iRON Tweezers Console Support Cartridge Storage Tool Stand and Charger Quick Tip Changer Brass Wool (inside) Antisplash Membrane Wiper B·iRON Console 7” Note: for references without console blue tooth device like PC or mobile can be connected. B 115T Nano B·iRON Tweezers Screw to...
Quick Start 1. Connection Connect the stand to the mains (100 - 240 V). 2. Cartridge Insertion and Charging Insert a cartridge into the tool (1) and place it into the charger on the stand (2). Note: Charge the tool completely (30 min) before using for the first time.
Page 5
The work screen shows the graph of the current tip temperature and the power supplied to the tip by moving the graph permantely to the left. Application Menu Tool Status Connected Tool Temperature and Power Grafi cs MENU JBC#1 WORK 24 W 450 ºC 18 W 350 ºC 12 W 250 ºC 150 ºC...
Operation The JBC Most Efficient Soldering System This revolutionary technology is able to recover tip temperature extremely quickly. This allows the user to work at a lower temperature. Work Charging and Hibernation When the tool is in the stand When the tool is lifted from the...
Page 7
The automatic recording can be paused by tapping the screen at the grafic area. The automatic recording stops also when the tool stops working. While the automatic recording is stopped, you can get the temperature/power value on a certain point by tapping the graph on the tablet screen. JBC#1 MENU CHARGE 450 ºC 24 W 348ºC...
Page 8
Includes a temperature resistant wiper for removing excess solder by gently tapping or wiping the cartridge tip. If the tip is very dirty, JBC recommends first cleaning it with the wiper to remove excess solder and then with Wiper the brass wool.
Page 9
Replacing Brass Wool 1. Lifting 2. Replacing Space Lift and remove the antisplash membrane. Replace the brass wool with a new one. Make sure that the brass wool is on the far left and that there is space for the wiper on the right. 3.
Page 10
Quick Tip Changer Save time and change cartridges safely without switching the station off. 1. Removing 2. Inserting 3. Fixing Reference Ring Place the tweezers with the Place the tweezers on top of Place the tweezers with the cartridge in the extractor slot the new cartridge and gently cartridge in the slot, so that its and pull to remove it.
Cartridge Tip Alignment Nano B·iRON Tweezers offers an intuitive cartrige tip alignment function. Cartridge tips can be rotationally and vertically aligned. Bushings for rotationally Wheel for vertically tip aligntment tip alignment Rotationally Tip Alignment Rotate the bushings slightly (1) to rotationally align the tips (2).
Menu Settings The B·iRON Console offers an intuitive user interface which provides quick access to station parameters. MENU Return to Work JBC#1 Tool ID Lock Parameters Sleep mode Sleep temperature Tool1 150ºC Locked Unlocked 2822 Hibernation delay Maximum Temperature Tool Status...
Page 13
- Connect the console/device via USB connection to the PC. - On the console/device notification bar at the top, open “USB Connection Settings” and select “MTP”. - On the PC copy the downloaded file to “IT706/internal share storage/JBC”. - Once copying is finished, disconnect the console/device from the PC.
- Maintain tip surface clean and tinned prior to storage in order to avoid tip oxidation. Rusty and dirty surfaces reduce heat transfer to the solder joint. - Do not use liquid such as alcohol, thinner or benzene to clean the console. - Repairs should only be performed by a JBC authorized technical service. Clean periodically...
Page 15
Safety It is imperative to follow safety guidelines to prevent electric shock, injury, fire or explosion. - Do not use the units for any purpose other than soldering or rework. Incorrect use may cause fire. - The power cord must be plugged into approved bases. When unplugging it, hold the plug, not the wire. - Do not work on electrically live parts.
Specifications B·iRON 115T Nano Tweezers B·iRON Station With Console: Without Console: Ref. BI115TUA BI115TUQA 120 V - N. America, Taiwan 120 V - N. America, Taiwan Ref. BI115TIA BI115TIQA 230 V - India 230 V - India Ref. BI115TA BI115TQA 230 V - Europe 230 V - Europe Ref.
Page 20
In order for the warranty to be valid, equipment must be returned, postage paid, to the dealer where it was purchased. Get 1 extra year JBC warranty by registering here: https://www.jbctools.com/productregistration/ within 30 days of purchase. This product should not be thrown in the garbage.