jbc DDSE-9C Instruction Manual page 10

Premium rework station with electric pump
Table of Contents

Advertisement

Specifications
Premium Rework Station with Electric Pump
DDSE-1B / DDSE-2B / DDSE-9B
- Total weight:
DDE-1B 120V 50/60Hz. Input fuse: 4A. Output: 23.5V
DDE-2B 230V 50/60Hz. Input fuse: 2A. Output: 23.5V
DDE-9B 100V 50/60Hz. Input fuse: 5A. Output: 23.5V
- Net Weight:
- Dimensions:
- Output Peak Power:
- Temperature Range:
- Idle Temp. Stability (still air):
- Tip to ground resistance:
- Tip to ground voltage:
- Ambient Operating Temperature: 10 - 40 ºC (50 - 104 ºF)
- Communicatio connectors:
- Robot connector:
MSE-A
- Net Weight:
- Dimensions:
- Air Pressure supply range:
- Vacuum at 6 Bar:
- Flow rate:
- Ambient operating temp.:
- Pedal connection
Complies with CE standards.
ESD protected.
10
9,25 kg (20.4 lb)
3,815 kg (8.41 lb)
148 x 120 x 232 mm (5.83 x 4.72 x 9.13 in)
150W per tool
90 - 450 °C (190 - 840 ºF)
±1.5 ºC (±3 ºF)
<2 ohms
<2mV RMS
USB-A / USB-B / Peripherals connectors
RJ12 for RS-232 protocol
0,7 kg (1.54 lb)
145 x 55 x 225 mm (5.71 x 2.17 x 8.86 in)
4-6 Bar
90% / 680 mmHg / 26.8 inHg
15 SLPM
10 - 40 ºC (50 - 104 ºF)