UGP 6C/8C/10C 
ORIFICE CLEANING INSTRUCTIONS 
FOR PIEZO AND ELECTRONIC 
IGNITION FRIDGES 
 Models Direct Vent (DV)
WARNING:
Installation of all gas components must
be done by a licensed gas technician. Improper
installation, adjustment, alteration, service or
maintenance can cause injury or property damage.
Refer to this manual. For assistance or additional
information consult a qualified installer, service agency
or the gas supplier.
!SAVE THESE INSTRUCTIONS!
FOR YOUR SAFETY IF YOU SMELL GAS
Open windows.
Do not touch electrical switches.
Extinguish any open flame
Immediately turn off gas supply and call your gas supplier
FOR YOUR SAFETY
Do not store or use gasoline or other flammable liquids in the
vicinity of this or any other appliance
in the absence of local national Fuel Gas Code, ANSI Z233.1 and in Canada
The installation of the appliance must conform with local codes or,
B149.2 Propane Storage and Handling Code

Advertisement

loading

Summary of Contents for Unique UGP 6C

  • Page 1 UGP 6C/8C/10C  ORIFICE CLEANING INSTRUCTIONS  FOR PIEZO AND ELECTRONIC  IGNITION FRIDGES   Models Direct Vent (DV) WARNING: Installation of all gas components must be done by a licensed gas technician. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
  • Page 2 UNIQUE UGP6C/8C/10C Direct Vent  Orifice Cleaning Instructions Tools required  Robertson Screwdriver ‐ Green #1 (burner box  screws)   12 mm wrench – removes thermocouple from  bracket if required   13 mm wrench ‐ removes older style orifice from  check point body.   10mm wrench ‐ removes new style orifice from check  point body.  Also remove 4 screws at the  Adjustable wrench – holds check point body in place  underside of the burner box while removing orifice.   Shut off the gas supply at the gas line.
  • Page 3 3. With orifice off, soak in a solvent such as paint New style orifice thinners or isopropyl alcohol and ensure it’s cleaned well. Old style orifice  Check to ensure the tip is clear  5. After orifice is removed. Remove bracket in order to run small brush down burner tube to Make sure orifice is spotless inside ...
  • Page 4 6. Once the orifice and burner tube is cleaned 9. Replace the outer burner box cover, but before reassemble the burner assembly and orifice back replacing the small viewing plate test fire the into the box. appliance to make sure the flame looks good and its align correctly under the boiler tube.

This manual is also suitable for:

Ugp 8cUgp 10c