Introduction; Safety Instructions; Storage - INFOSEC C3 MPPT User Manual

Table of Contents

Advertisement

Available languages

Available languages

In order to make sure that this product is correctly installed and used appropriately, we highly
advise you to read this user guide very carefully.

INTRODUCTION

C3 MPPT and C3+MPPT range is a multi-function inverter/charger, combining several functionalities:
inverter, MPPT solar charger and battery charger that offer a power supply in a compact design. Its
user-friendly LCD screen with user-configurable buttons allows setting the battery charging current,
the AC/solar charger priority, and the acceptable input voltage based on different applications.

SAFETY INSTRUCTIONS

IMPORTANT!
Installing and connecting C3 MPPT / C3+MPPT in a way that does not comply with accepted
practices releases Infosec Communication from any liability.
 Risk of electric shock:
 C3 MPPT / C3+MPPT uses potentially hazardous voltages. Do not attempt to disassemble this
equipment, as it does not contain accessible components that can be repaired by users, fuse change
excepted.
 Any fixing should be performed by qualified technicians only.
 In the event of an emergency situation, switch C3 MPPT / C3+MPPT to the "Off" position and
disconnect the unit from the AC power supply and from any other source of power.
 Should C3 MPPT / C3+MPPT be out of order, please refer to the section: "trouble shooting" and
call the hotline.
 Connected products:
 Combined C3 MPPT / C3+MPPT and connected equipment leakage current should not exceed
3,5 mA.
 Make sure that the connected load does not exceed C3 MPPT / C3+MPPT capabilities. To ensure
an improved backup time and longer battery lifetime, we recommend a load equivalent to 1/3 of the
nominal power.
 Do not plug C3 MPPT / C3+MPPT input into its own output terminal.
 Do not plug C3 MPPT / C3+MPPT into a power strip or surge suppressor.
 C3 MPPT / C3+MPPT was designed for domestic appliances and personal computers.
 Due to excessive consumption, laser printers should not be connected to C3 MPPT / C3+MPPT
 Please replace the fuse only with the same type and amperage in order to avoid fire hazards.
 Correct disposal of the device:
 Install C3 MPPT / C3+MPPT in a temperature and humidity-controlled room free of conductive
interference.
 C3 MPPT / C3+MPPT should not be exposed to direct sunlight or sources of heat. Do not cover
the ventilation slots.
 Disconnect C3 MPPT / C3+MPPT from AC power and from any other source of power before
cleaning with a damp cloth (no cleaning products).
 Do not leave any recipients containing liquid on or near C3 MPPT / C3+MPPT.

STORAGE

Do not keep or use C3 MPPT / C3+MPPT in any of the following environments:
 Any area with combustible gas, corrosive substances or heavy dust.
 Areas with excessively high or low temperature (above 55°C or below 0°C) and humidity of
more than 90%.
 Areas exposed to direct sunlight or near sources of heat.
 Areas subject to major vibration.
 Outside
INFOSEC UPS SYSTEM - 4, rue de la Rigotière - 44700 Orvault - FRANCE - www.infosec-ups.com
Hot Line – Tel + 33 (0)2 40 76 15 82 - Fax + 33 (0)2 40 94 29 51 - hotline@infosec.fr – 06 15 AA 59 203 33