Display Setting - INFOSEC C3 MPPT User Manual

Table of Contents

Advertisement

Available languages

Available languages

Solar power balance:
When enabled, the solar
input power will be
automatically adjusted
31
according to the connected
load power.
(Only available for C3+
MPPT 4000-48 and 5000-
48 models)

3-5. Display Setting

The LCD display information will be switched in turns by pressing the "UP" or "DOWN" key. The
selectable information is switched in the following order:
-
input voltage,
-
input frequency,
-
photovoltaic voltage,
-
MPPT charging current,
-
MPPT charging power,
-
battery voltage,
-
output voltage,
-
output frequency,
-
load percentage,
-
load in VA,
-
load in Watt,
-
DC discharging current,
-
main CPU Version
-
second CPU Version.
Selectable information
Input voltage/Output voltage
(Default Display Screen)
Input frequency
PV voltage
INFOSEC UPS SYSTEM - 4, rue de la Rigotière - 44700 Orvault - FRANCE - www.infosec-ups.com
Hot Line – Tel + 33 (0)2 40 76 15 82 - Fax + 33 (0)2 40 94 29 51 - hotline@infosec.fr – 06 15 AA 59 203 33
Solar power balance
enabled (Default):
Solar power balance
disabled:
LCD display
Input Voltage=230V, output voltage=230V
Input frequency=50Hz
PV voltage=60V
If selected, the solar input power
will be automatically adjusted
according to the following formula:
Max. input solar power = Max.
battery charging power +
Connected load power.
If selected, the solar input power
will be the same as the maximum
battery charging power no matter
how much load is connected. The
maximum battery charging power
will be based on the setting
current in program 02.
(Max. solar power = Max. battery
charging power)
22

Hide quick links:

Advertisement

Table of Contents
loading