Step 9 Position Mechanism unit (CR14) according to the
diagram show.
Step 10 Connect 50P FFC cable at the connector (CN2801) on
Main P.C.B..
Step 11 Connect 11P FFC cable at the connector (CN2805) on
Main P.C.B..
Step 12 Connect 5P cable at the connector (CN8002) on USB
P.C.B..
Step 13 Position SMPS and AC Inlet P.C.B. according to the
diagram show.
Step 14 Attach original cable with extension cable (REXX0680)
(11P cable from CN2701 to CN5050).
Step 15 Connect extension cable (REEX0930) (17P cable from
CN2802 to CN5050).
Step 16 Attach original cable with extension cable (REXX0683)
(8P cable from H5801 to CN5500).
Step 17 Attach original 1P grounding wire with ground cable.
Step 18 Service and repair AC Inlet P.C.B. and SMPS P.C.B.
respectively.