Zoeller 1263 Quick Start Manual
Zoeller 1263 Quick Start Manual

Zoeller 1263 Quick Start Manual

Sewage pump

Advertisement

ZoellerAtHome.com
Zoeller
is a registered trademark
®
of Zoeller Co. All Rights Reserved.
ATTACH YOUR RECEIPT HERE
Serial Number
Questions, problems, missing parts? Before returning to your retailer, call our customer
service department at 1-800-584-8089, 7:30 a.m. - 5:00 p.m., EST, Monday - Friday.
Purchase Date
1
© 2020. All rights reserved.
SEWAGE PUMP
MODEL #1263
Español p. 17
SW1316 B

Advertisement

Table of Contents
loading

Summary of Contents for Zoeller 1263

  • Page 1 SEWAGE PUMP ZoellerAtHome.com MODEL #1263 Zoeller is a registered trademark ® of Zoeller Co. All Rights Reserved. Español p. 17 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-800-584-8089, 7:30 a.m.
  • Page 2: Safety Information

    SAFETY INFORMATION CAUTION Please read and understand this entire manual before attempting to assemble, operate, or install the • PRODUCT DAMAGE MAY RESULT. product. Make certain that the power source conforms to the requirements of your equipment. • NOTE: Pumps with the “UL” Mark and pumps with the “US” mark are tested to UL Standard •...
  • Page 3: General Pump Information

    3. The pump will turn off automatically when the water provide a solid base. level in the basin reaches the “off” level. Item On Level Off Level 1263 10.25 in. 5 in. © 2020. All rights reserved. © 2020. All rights reserved.
  • Page 4 INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS 4. Place the pump inside the basin with the switch 7. Use a 2-step PVC glue system (not included) to join positioned away from incoming water. pipe and any fittings needed. Incoming water Switch 5. Be sure the float switch is at least 1 in. away from the 8.
  • Page 5 INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS 10. Install a 2 in. check valve (not included) above the 13. Attach power supply cord to discharge pipe using union to prevent back-flow. cable or zip ties (not included) to allow the float switch Check to move freely.
  • Page 6: Troubleshooting

    4. Water inflow exceeds pump capacity. 4. Re-check sizing calculations to PERFORMANCE determine proper pump size. Item Shut Off Discharge Ft. of Head Flow (GPM) Number Head (Ft.) Size 1263 2 in. © 2020. All rights reserved. © 2020. All rights reserved.
  • Page 7: Care And Maintenance

    WARRANTY TROUBLESHOOTING This product is warranted for three years from the date of purchase. Subject to the conditions Problem Possible Cause Corrective Action hereinafter set forth, the manufacturer will repair or replace to the original consumer, any portion of Pump operates, 1.
  • Page 8: Repair Parts

    WIRING DIAGRAM REPAIR PARTS MODEL ITEM DESCRIPTION 1263 BLACK SWITCH Cord Kit Includes cord w/o-ring, case o-ring (115x4 NBR), clamp screws 025390 (M5-0.8x16), cap screws (M6-1.0x15), GND screw (M4-0.7x6.0) Capacitor Kit Includes capacitor, cap screws (M6-1.0x15), mounting screw (M4- 025383 0.7x6), case o-ring (115x4 NBR)
  • Page 9 © 2020. All rights reserved.

Table of Contents