NOTE: Make sure the hose is secure so there are no
leaks. Direct the hose toward the drain, making sure
that there are no kinks that will stop the warter flowing.
Place the end of the hose into the drain and make sure
the end of the hose is down to let the water flow
smoothly. When the continuous drain hose is not used,
ensure that the drain plug and knob are installed firmly
to prevent leakage.
· When the water level of the bottom tray reaches a
predetermined level, the unit beeps 8 times, the
digital display area shows "P1" . At this time the air
conditioning/dehumidification process will
immediately stop. However, the fan motor will
continue to operate(this is normal). Carefully move
the unit to a drain location, remove the bottom drain
plug and let the water drain away. Reinstall the bottom
drain plug and restart the machine until the "P1"
symbol disappears. If the error repeats, call for service.

Maintenance

Safety Precautions

· Always unplug the unit before cleaning or servicing.
· DO NOT use flammable liquids or chemicals to clean the unit.
· DO NOT wash the unit under running water. Doing so causes electrical danger.
· DO NOT operate the machine if the power supply was damaged during cleaning. A damaged
power cord must be replaced with a new cord from the manufacturer.

Air Filter Cleaning

Upper filter
(take out)
lower filter B
(take out)
Remove the air filter

Unit Cleaning

Clean the unit using a damp, lint-free cloth and mild detergent. Dry the unit with a dry, lint-free
cloth.
lower filter A
(Press the grill down
slightly and pull the
lower filter A out at
the same time)
NOTE: Be sure to reinstall the bottom drain plug firmly
to prevent leakage before using the unit.
When the water drainage function is not in use,
keep the upper and the lower drain plug firmly to
the unit to get rid of choking. When the drain plug
is not in use, keep it carefully to prevent children
from choking.
CAUTION
DO NOT operate the unit without filter
because dirt and lint will clog it and reduce
performance.
Maintenance Tips
· Be sure to clean the air filter every 2 weeks for
optimal performance.
· The water collection tray should be drained
immediately after P1 error occurs, and before
storage to prevent mold.
· In households with animals, you will have to
periodically wipe down the grill to prevent
blocked airflow due to animal hair.