6-­‐3.   T emperature   S ensor
Parameter table attached:
THE PARAMETER OF THE INDOOR COIL AND INDOOR ROOM SENSOR
(R(0)=15k B(0/100)=3450)
Temperature(℃)
Resistance(k)
-20
-19
-18
-17
-16
-15
-14
-13
-12
-11
-10
-9
-8
Voltage(V)
38.757
0.58143512
36.844
0.60795346
35.038
0.63530819
33.331
0.66352684
31.719
0.69257720
30.196
0.72246147
28.755
0.75321223
27.392
0.78480857
26.103
0.81722911
24.882
0.85051031
23.727
0.88458737
22.632
0.91951536
21.594
0.95527085
Temperature(℃)
Resistance(k)
31
4.292
32
4.137
33
3.989
34
3.847
35
3.711
36
37
3.455
38
3.335
39
3.219
40
3.108
41
3.001
42
2.899
43
2.801
48
Voltage(V)
2.715076661
2.76063657
2.805589174
2.850117358
2.894109636
3.58
2.937788018
2.980713033
3.023117961
3.065272268
3.106725146
3.147759536
3.187898487
3.227439565