1.1 Safety instructions and warnings 1.4 Description Only use this display The 52U is a multipurpose device. – in a way according to its intended Depending on the programmed basic function, purpose the device operates like – if its technical condition is perfect •...
Page 3
After pressing any key, only the menu item setting is displayed. 52U: basic operating mode f. Pressing the right key, the menu item setting will be switched to the next value. If figures are to be input (e.g. when setting the scaling factor), select first the decade 1.
Page 4
4.1 Polarity of the inputs npn: switching for 0 V pnp: switching for +U B 4.2 Switching on the 30 Hz filter (INP A) 30 Hz filter off (f max ) 30 Hzfilter on 4.3 Multiplying factor (totalizer) It can be set from 00.0001 up to 99.9999.
Page 5
Electronic display counter 4.10 Display mode (frequency meter) with 2 totalizing ranges 52U: basic operating mode Value conversion and display in 1/s Value conversion and display in 1/min 1. Description • 6-digit dislay counter with Reset function 4.11 Max. time to wait until “0” is displayed •...
Page 6
4.1 Polarity of the inputs 4.6 RESET mode (totalizer 1) manual reset via the red npn: switching for 0 V RESET key and electrical reset via the RESET input pnp: switching for +U B no reset (red RESET key and RESET input locked) 4.2 Switching on the 30 Hz filter (INP A) The filter provides input only electrical reset via the...
Page 7
Electronic totalizer and time meter 4.8 End of programming 52U: basic operating mode The programming routine is repeated once more. The values set until now can be checked and mod- ified. 1. Description • 6 digit totalizer and time meter with Reset...
Page 8
4.5 Decimal point (totalizer) 4. Programming routine The programmable parameters of the device are The decimal point defines described below, in the order in which they can the way of displaying the be set. The device is fully programmed after one count values.
Page 9
4.8 Operating mode (time meter) 4.10 RESET mode (time meter) manual reset via the red Time unit: seconds (accu- RESET key and electrical racy depending on posi- reset via the RESET input tion of the decimal point*) Time unit: minutes (accu- no reset (red RESET key racy depending on posi- and RESET input locked)
Page 10
Electronic time meter with 2 time ranges 52U: basic operating mode 4. Programming routine 1. Description • 6 digit time meter with Reset function The programmable parameters of the device are • Red LED display, character height 8 mm described below, in the order in which they can •...
Page 11
4.3 Input mode (time meter) 4.5 Decimal point The decimal point defines the resolution of the pro- grammed time unit. Start/Stop via Inp B. Counting while Inp B (Gate) not active or open 1/10 (0,1) 0.00 1/100 (0,01) Start/Stop via Inp B. 0.000 1/1000 (0,001) Counting while Inp B (Gate) active (High level with...
4.8 End of programming Frequency measurement: Accuracy : < 0.1 % Measuring principle: < 38 Hz: period measurement The programming routine > 38 Hz: gating time measurement is repeated once more. gating time = 26,3 ms The values set until now can be checked and mod- Time count ranges: ified.
6. Terminal assignment 7. Delivery includes: 1 10 ... 30 V DC 1 Digital display 2 0 V GND 1Panel mounting clip 3 INP A 1 Bezel for screw mounting, panel cut out 4 INP B 50 x 25 mm Reset 1 Bezel for clip mounting, panel cut out 50 x 25 mm...