ViziT BVD-343 Series Quick Start Manual

ViziT BVD-343 Series Quick Start Manual

Doorstation

Advertisement

Doorstation
BVD-343x
apartment doorphones and video doorphones of Series 300.
The following models are available:
Model
RF
u
BVD 43R*
-3
u
BVD 43R P*
-3
С
u
BVD 43RVP*
-3
u
BVD 43RT*
-3
BVD 43T
-3
BVD 43T P
-3
С
BVD 43TVP
-3
Abbreviations used in the model index:
R
- RF-keys reader (PROXIMITY,
T
- TM-keys reader
(TM-key: DS1990A / iBUTTON)
С
- Colour camera
V
- B/W camera
Р
-
Pinhole lens
*
Note: Only VIZIT-RF-2 keys from VIZIT
Contents of
VIZIT
doorphone / video doorphone, its features, order of programming and operation are described in the
Control Unit
BUD-302 BUD-302M BUD-302K-20
/
operates together with Control Units
1
2
3
4
5
Speaker
1
Camera
2
Illumination
3
for the camera
Microphone
4
Figure
Camera
Reader
Pinhole Lens
Colour with
TM
illumination
u
u
u
u
u
u
125
kHz)
®
are supported.
/
BUD-302M BUD-302
TM-keys reader
5
RF-keys reader
6
4-digit LED
7
1 -
Doorstation BVD-343x
B/W with
illumination
u
u
operating instruction.
,
and
BUD-302K-20
7
6
BVD
-343х
in
VIZIT
multi

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BVD-343 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ViziT BVD-343 Series

  • Page 1 (TM-key: DS1990A / iBUTTON) С - Colour camera - B/W camera Р Pinhole lens Note: Only VIZIT-RF-2 keys from VIZIT ® are supported. Contents of VIZIT doorphone / video doorphone, its features, order of programming and operation are described in the...
  • Page 2 PARTS LIST BVD-343х Operating Instruction Fasteners Screw - 4х4 Concrete Insert 6х30 SAFETY INSTRUCTIONS The product does not contain voltage above Connect the earthing wire (green/yellow) of the doorstation to the protective earth. WARNING § Do not perform any connections or repair when the power is on! §...
  • Page 3 Locate the doorstation to avoid: -direct rays of the sun or other light sources -direct hit of rain and snow 50 сm 68° Figure Recommended doorstation position and the camera field of view Coax cable holder Terminals to connect the Control Unit Earthing terminal...
  • Page 4 +E 4 SP- 3 Green White SP+ 2 GND 1 Figure Doorstation BVD-343x with control unit BUD-302 (M, K-20) electromagnetic lock VIZIT-ML400 and button EXIT 300 DOORSTATION Electromagnetic BVD 43 х BK-4V(MV) Lock VIZIT-ML400 VO 9 RVS-4 VG 8 TX 7...
  • Page 5 Do not use electromagnetic locks with less than 20 Ohm impedance and not provided with a built-in degaussing module. Do not use electromechanical locks with less than 10 Ohm impedance. If you use an electromechanical lock, a damper diode (50V / 1A , not supplied) shall be connected to its terminals (See Fig.

This manual is also suitable for:

Bvd-343rBvd-343rcpBvd-343rvpBvd-343rtBvd-343tBvd-343tcp ... Show all

Table of Contents