Utilitech UT-5412 Manual page 6

Motion sensor lighting control
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION INSTRUCTIONS
4.
Test the sensor:
a. Turn on the circuit breaker and light switch. The
sensor (C) has a 1-1/2 minute warm up period
before it will detect motion.
b. Turn the RANGE control to the mid position (halfway
between MIN and MAX) and the ON-TIME control to
the TEST position.
c. Loosen the clamp screw (1) in the sensor ball joint
(2) and gently rotate the sensor (C).
d. Walk through the coverage area noting where you
DUH ZKHQ WKH OLJKWV WXUQ RQ DOVR WKH /(' ZLOO ÀDVK
several times when motion is detected). Move the
sensor (C) head up, down, or sideways to change
the coverage area. Keep the sensor at least 1 in.
(2.5 cm) away from the lamps.
e. Adjust the RANGE as needed. RANGE set too high
may increase false triggering.
f. Secure the sensor (C) head by tightening the clamp
screw (1). Do not overtighten the screw.
g. Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 10 minutes).
Important: Avoid aiming the control at:
– Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
– $UHDV ZKHUH SHWV RU WUDI¿F PD\ WULJJHU WKH FRQWURO
– 1HDUE\ ODUJH OLJKWFRORUHG REMHFWV UHÀHFWLQJ OLJKW
may trigger the shut-off feature. Do not point other
lights at the sensor.
Note: ,I WKH ¿[WXUH LV PRXQWHG KLJKHU WKDQ  IW 
m), aiming the sensor down will reduce coverage
distance. The detector is less sensitive to motion
directly toward it.
Important: ,I WKH ¿[WXUH LV PRXQWHG KLJKHU WKDQ  IW
,I WKH ¿[WXUH LV PRXQWHG KLJKHU WKDQ  IW
4
ON-TIME
10 5 1 TEST
2
Least Sensitive
6
Bottom of Senso
r
RANGE
ON-TIME
RANGE
MIN
MAX
10 5 1 TEST
MIN
MINUTES
1
Aim Down
Aim Up
Most Sensitive
Lowes.com
MAX
C