CLEANING AND MAINTENANCE

We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use
alcohol or solvents!
There are no serviceable parts inside the device except for the fuse. Maintenance and service operations are
only to be carried out by authorized dealers.

Replacing the fuse

If the fine-wire fuse of the device fuses, only replace the fuse by a fuse of same type and rating.
Before replacing the fuse, unplug mains lead.
Procedure:
Step 1: Open the fuseholder on the rear panel with a fitting screwdriver.
Step 2: Remove the old fuse from the fuseholder.
Step 3: Install the new fuse in the fuseholder.
Step 4: Replace the fuseholder in the housing.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by a special power supply
cable available at your dealer.
Should you have further questions, please contact your dealer.

TECHNICAL SPECIFICATIONS

Power supply:
Power consumption (max.):
Output power sine:
Stereo 4 Ohm / 100 V:
Stereo 8 Ohm:
8 Ohm bridged:
Frequency range:
Distortion:
S/N-ratio:
Input sensitivity:
Input impedance:
Zone input-connectors:
Link:
Zone output-connectors:
Controller connector:
LED indicators (per channel):
Dimensions:
Minimum mounting depth:
Weight:
Please note: Every information is subject to change without prior notice. 19.04.2007 ©
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
230 V AC, 50 Hz ~
1250 W
12 x 50 W
12 x 25 W
6 x 100 W
20 Hz - 20 kHz
0.01 % (1 kHz)
85 dB
250 mV
>47 kOhms
6 x stereo RCA
RS-232
Terminal blocks
RJ45
Signal
482 x 420 x 102 mm
450 mm
11 kg
27/27