Air purification device with advanced cold plasma technology (40 pages)
Summary of Contents for Jonix maximate
Page 1
JONIX maxima USE AND MAINTENANCE MANUAL AIR PURIFICATION DEVICE WITH ADVANCED COLD PLASMA TECHNOLOGY MADE IN ITALY...
Page 2
These instructions are translated from Italian (the original language). JONIX S.p.A. reserves every right concerning this manual, including the right to make any necessary change or improvement to its products and to the manual at any time and without notice. It is forbidden to reproduce in full or in part...
1.3 - SYMBOLS 2 - WARNINGS AND GENERAL PROHIBITIONS 3 - THE OPERATING SYSTEM 4 - TECHNICAL DATA 4.1 - COMPONENT DESCRIPTION JONIX maximate 4.1.1 - Technical features JONIX maximate 5 - RECEPTION, TRANSPORT AND STORAGE 5.1 - PACKAGING 5.2 - HANDLING AND TRANSPORT 5.3 - INSPECTION UPON RECEPTION...
Page 4
This manual contains the information and all that is required for the transportation, installation, use and maintenance of the JONIX sanitation and filtering module. maximate Improper installation of the device and/or failure to comply with the instructions in this manual, may invalidate the warranty that the Manufacturer issues for its products.
In particular, if equipment maintenance is carried out in a way that is not in compliance with the instructions supplied, or in a way to jeopardise integrity or modify features, JONIX S.p.A. is relieved from any liability inherent to safety of persons and faulty operation of the equipments.
JONIX for another copy or download the document S.p.A. from www.jonixair.com. Repairs and maintenance work must be carried out by JONIX authorised S.p.A. staff or by qualified staff according to the provisions set out by this manual. Do not alter or tamper with the device as it can lead to hazards and the manufacturer of the device shall not be liable for any damage caused.
Page 7
When installing, commissioning and operating this product, it is mandatory to observe the requirements and instructions specified in this manual. disclaims any liability for damage caused to people, animals or JONIX S.p.A. property due to installation, adjustment and maintenance errors or by improper use.
The sanitising cabinet is equipped with a double grid with movable fins to direct the supply air flow. Compact, portable and quiet, the JONIX module maximate quickly and effectively meets the requirements of reducing bacterial and particulate load.
J O N I X m a x i m at e 4 - TECHNICAL DATA JONIX maximate FRONT VIEW 4.1 COMPONENT DESCRIPTION JONIX maximate 01 Adjustable 2 way air outlet register 07 Pre filter G4 – Coarse dust filter EN 779: 2012...
JONIX maximate must remain intact until they are assembled. The materials that were not installed for technical requirements are supplied with suitable enclosure secured to the inside or outside of the device itself.
J O N I X m a x i m at e 6 - INSTALLATION AND COMMISSIONING ATTENTION! Before carrying out any operation on the devices read ALL the instructions in this manual carefully. Definitions: USER: USER/OPERATOR: QUALIFIED STAFF: Person, organisation or Individual been Individuals who have completed a...
- The device has been exposed to the elements. - A malfunction persists despite all the installation and/or maintenance procedures have been performed properly. IMPORTANT The installer and the user, when using the JONIX device, maximate must take into account and solve all the other types of risk associated with the system.
Using power supply that does not meet the requirements requested by the device could resolve in damaging the device or part of it. • The electrical mains of the JONIX device must be used for the device only, there maximate must be no other devices powered by the same power line.
NOTE: the straight plug(A) is located in the top exit. The straight connector(B) comes supplied. Fig. 02: Once connected to the mains supply, the JONIX module maximate is ready to work. In order to turn on the device act on the selector (positioned on the panel) turning it to I.
6.8 USER INTERFACE AND MENU NAVIGATION is provided with a touch screen, allowing the user to control device status and JONIX maximate to modify its operation as needed. 6.8.1 Main screen It allows to check quickly the device status and to modify its operation mode.
Page 16
Alarms notifications and alarms screen: When the Jonix will notice that the user intervention is needed, this alert state will be shown with the appearance of a notification on the icon of the device part that has caused the alarm.
J O N I X m a x i m at e 6.8.2 Ionisers screen It displays the detailed status of the modules J O N I X m a x i m at e and allows the management of each of them according to the user needs.
J O N I X m a x i m at e 6.8.4 Fan screen Shows a more detailed fan status and allows the J O N I X m a x i m at e management of its operation status as needed. a) Air flow set point (m /h): through the buttons “-“...
• Device On/Off. • Ionising modules On/Off. • Increase/decrease of the fan speed. The password of the device JONIX is: 100. It is possible to modify maximate the password holding the button to the side of the currently set password.
The setting of the start time of the next slot (in the same day or in another) implies the end of the previous time slot. f) Machine status: enable / disable JONIX maximate g) L Module: enable / disable the left ionising module.
J O N I X m a x i m at e 6.8.5.5 Alarms History Shows the list of all the alarm messages displayed J O N I X m a x i m at e from the device in the set time lapse. 6.8.5.6 Maintenance Maintenance screens of the ionising modules and J O N I X...
J O N I X m a x i m at e Filters Maintenance J O N I X m a x i m at e Maintenance operations on the corresponding filter can be recorded in the system from this menu.
J O N I X m a x i m at e 6.8.5.9 Configuration a) Advanced configuration: restricted J O N I X m a x i m at e menu technical support, accessible to the final user. 6.8.5.10 Multimedia screen Shows the links to all the multimedia content J O N I X m a x i m at e...
The frequency of the operations to be performed to ensure proper maintenance of the device depends mainly on the quality of the treated air. JONIX maximate Air can be especially harmful for condensers when it contains polluting or aggressive substances such as:...
J O N I X m a x i m at e 7.2.1 Cleaning the Ionising Tubes Clean the ionising tubes every time it is shown on the display. Fig. 03: Switch off the unit by turning the On / Off switch to the 0 position. Remove the plug connected to the mains.
Page 26
J O N I X m a x i m at e Fig. 07: Clean the glass using a damp cloth. Do not use liquid cleaners or sprays, soap or the like. Check that the tube is in good conditions: there must not be any cracks or other damage;...
Page 27
J O N I X m a x i m at e Fig. 11: If the operation is difficult to perform, pull slightly the earthing spring so that it is not in contact with the surface of the tube. Check that the earthing spring is in contact with the outer mesh once the ionising tubes have been screwed back into...
14000 hours of operation. - filters: the components have the function of barrier, and they tend to saturate so that eventually they will obstruct the air flow. The detection devices internal to JONIX signal how maximate necessary is an operation of replacement in order to maintain a smooth functioning of the device.
J O N I X m a x i m at e 7.3.1 Replacing the ionising tubes Replace the ionising tubes every time it is notified on the display. Fig. 13: Switch off the unit by turning the On / Off switch to the 0 position. Remove the plug connected to the mains.
Page 30
J O N I X m a x i m at e Fig. 17: Screw delicately the ionising tube holding on to the base (green part). ATTENTION: do not overtighten the screw after reaching its end stop. Fig. 18: If the operation is difficult to perform, pull slightly the earthing spring so that it is not in contact with the surface of the tube.
Page 31
J O N I X m a x i m at e Register the maintenance operation done using the display: J O N I X J O N I X m a x i m at e m a x i m at e J O N I X J O N I X m a x i m at e...
J O N I X m a x i m at e 7.3.2 Replacing the filters Replace the filters every time it is notified on the display. Fig. 20: Type of filters on the JONIX device: maximate a) Absolute filter H13...
J O N I X m a x i m at e Fig. 23: Pull the filter locking tabs out. Extract the filters. Put the new / clean filters back in place. Push the filter locking tabs towards the device until they click. Fig.
J O N I X m a x i m at e Fig. 27: Refit the lower panel. Turn on the unit by acting on the disconnector On / Off switch to the position I. Close the front doors. 230 VOLT ALIMENTAZIONE ELETTRICA POWER SUPPLY SPANNUNGSVERSORGUNG...
Page 35
J O N I X m a x i m at e Fig. 30: Refit the lower panel. Turn on the unit by acting on the disconnector On / Off switch to the position I. Close the front doors. 230 VOLT ALIMENTAZIONE ELETTRICA POWER SUPPLY SPANNUNGSVERSORGUNG...
J O N I X m a x i m at e 9 - OPERATIONAL CHECK AND TROUBLESHOOTING This section summarises the most common problems that may arise when using the unit. Before contacting customer services, carry out the checks listed below. PROBLEM POSSIBLE CAUSE SOLUTION...
J O N I X m a x i m at e 10 - DISPOSAL When JONIX devices are no longer used they must be disposed of in compliance with maximate the regulations in force in the country of installation. The unit consists of the following materials: •...
J O N I X m a x i m at e EXPLODED JONIX maximate 1305 75.2 1155 75.2 : ambient air. : ionised air flow.
Page 40
J O N I X m a x i m at e NOTES ............................................................................................................................................................................................................................................................................................................................................................................................
Page 41
J O N I X m a x i m at e ............................................................................................................................................................................................................................................................................................................................................................................................
Page 42
J O N I X m a x i m at e ............................................................................................................................................................................................................................................................................................................................................................................................
Page 44
JONIX S.p.A. Società Benefit Operational Headquarters: Registered Office: Research and Development info@jonixair.com Headquarters: Viale Spagna 31/33 Via dell’Artigianato, 1 Certified mail: jonixsrl@legalmail.it 35020 Tribano (PD) - Italy 35020 San Pietro Viminario Via Tegulaia 10/b web: www.jonixair.com tel +39 049 9588511 (PD) –...
Need help?
Do you have a question about the maximate and is the answer not in the manual?
Questions and answers