Page 1
m i n i m at e p l u s USE AND MAINTENANCE MANUAL AIR PURIFICATION AND AIR SANITIZATION DEVICE ACTIVE SANITISATION OF INTERNAL COMPONENTS WITH ADVANCED COLD PLASMA TECHNOLOGY...
Page 2
JONIX S.p.A. make any necessary change or improvement to its products and to the manual at any time and without notice. It is forbidden to reproduce in full or in part this manual without S.p.A.’s consent.
2 - WARNINGS AND GENERAL PROHIBITIONS 2.1 - SAFETY SIGNS 3 - THE OPERATING SYSTEM 4 - TECHNICAL DATA JONIX minimate plus 4.1 - COMPONENTS DESCRIPTION JONIX minimate plus 4.1.1 - Technical characteristics JONIX minimate plus 4.1.2 - Spare parts available on order 5 - RECEPTION, TRANSPORT AND STORAGE 5.1 - PACKAGING...
Page 4
This manual contains the information and anything deemed necessary for the transport, installation, use and maintenance of the active sanitizing and air purification device JONIX minimate plus Improper installation of the device and/or failure to comply with the instructions in this manual, may void the warranty that the Manufacturer issues for its products.
1.2 RESPONSIBILITY Failure to comply with the instructions contained in this Use and Maintenance Manual releases JONIX S.p.A. from any liability. For any data not included or not deducible from the following pages it is recommended to consult JONIX S.p.A. directly.
m i n i m at e p l u s 1.3 GENERAL SAFETY INSTRUCTIONS, SYMBOLS AND DEFINITIONS 1.3.1 General safety instructions Any intervention, of whatever nature, on the device must be carried out by prior and careful reading of this manual in all its parts, with particular reference to SAFETY. It is essential, therefore, that the device is used in accordance with its intended use and with this manual.
m i n i m at e p l u s 1.3.3 Definitions Below are the definitions of the main terms used in the user manual. MANUFACTURER Individual or juridical person who designs and/or manufactures the device and is responsible for its conformity for the purpose of placing it on the market under his own name or trademark.
JONIX or download the S.p.A. document from www.jonixair.com. It is the user's responsibility to ensure that, if this document is modified by JONIX , only the updated versions of the Manual are actually present at the points S.p.A. of use.
Page 9
The transport, handling, installation, commissioning and decommissioning of this product must only be performed in accordance with the requirements and instructions specified in this manual. Any liability of JONIX is excluded for damage caused to persons, animals S.p.A. or property, whether due to transportation, installation, adjustment, maintenance, decommissioning or misuse.
Page 10
• It is the duty of the user to perform all the maintenance operations on the device reported in this manual. • If a malfunction not indicated in this manual occurs, disconnect the power supply to the device and consult your dealer and/or JONIX S.p.A. • Only trained and qualified personnel can perform maintenance operations other than those specified in this manual.
m i n i m at e p l u s 2.1 SAFETY SIGNS Check the condition of the safety pictograms periodically and replace them if necessary. The safety signs on the machine are as follows: Pictogram 1 Pictogram 2 Pictogram 3 Pictogram 4 Pictogram 5...
3 - THE OPERATING SYSTEM The range JONIX minimate consists of a variety of models to satisfy all air purification needs. Immediately operational, it does not require any complex operation for its installation. Compact,...
Page 13
The device JONIX minimate plus is equipped with two filtration stages. The medium filter F7 combined with the absolute filter H13 or H14 allow the reduction of airborne fine dusts and to ensure a very high degree of filtration.
4 - TECHNICAL DATA JONIX minimate plus Fig. 1 4.1 COMPONENT DESCRIPTION JONIX minimate plus Display Touch screen 12 Adjustable 2 way air outlet register Flat Plug Power Socket Inlets with On/Off Rocker Switch...
4.1.1 Technical features JONIX minimate plus The technical characteristics and relevant data are shown on the nameplate together with the serial number identifying the device. Dimensions Max power (*) Flow...
5 - RECEPTION, TRANSPORT AND STORAGE 5.1 PACKAGING The JONIX minimate plus device is shipped in special protective packaging that must be kept intact until installation. The materials that were not installed for technical requirements are supplied with suitable enclosure secured to the inside or outside of the device itself.
In case of prolonged storage before installation, the device must be protected from dust, weather and kept away from heat and vibration. Do not allow the device to come into contact with corrosive substances. JONIX S.p.A. declines all liability for damage due to poor handling, transportation and storage. 17 - 76...
6 - INSTALLATION AND COMMISSIONING JONIX S.p.A. disclaims any liability for failure to comply with the safety and prevention standards as described below. The Manufacturer also disclaims any liability for damage caused by improper use of devices and/or alterations carried out without prior authorisation.
Page 19
m i n i m at e p l u s • Do not try to perform maintenance work on the device, except where specified in this manual. Opening or removing the outer casing may expose you to dangerous live parts or may involve other risks.
• Disconnect the device from the power supply and contact JONIX S.p.A. or a dealer for service when any of the following cases occur: - the internal parts of the device have come into contact with water or other liquids of any kind;...
Page 21
m i n i m at e p l u s Fig. 4: Take the keys attached to the upper grille and open the front maintenance access panel. Fig. 5: Take the power cord and the ionising pipes. Handle ionising pipe carefully as it is fragile.
Page 22
m i n i m at e p l u s ATTENTION: do not overtighten the screw after reaching its end stop. Check that the earthing spring is in contact with the outer mesh once the ionising tubes have been screwed back into place. Otherwise contact the manufacturer. Fig.
Page 23
m i n i m at e p l u s Fig. 10: Gently tighten the ionising pipe by gripping it at the base (green part), positioning it in its seat above the fan. If the operation is difficult to perform, pull slightly the earthing spring so that it is not in contact with the surface of the tube.
m i n i m at e p l u s Fig. 13: Close the front maintenance access panel with the maintenance access key. The device is ready for use (see paragraph 6.6 "USING THE DEVICE"). 6.3 OPERATING SITE CHARACTERISTICS The environment in which the device is placed must have the following characteristics: - air temperature between 0°C and 40°C;...
Fig. 14: The device JONIX minimate plus can be easily moved in various environments, as it is equipped with 4 360° castor wheels. It can be locked and secured in its operating position thanks to the brakes that all wheels are equipped with.
6.5 ELECTRIC POWER SUPPLY The JONIX minimate plus device is ready for connection to the civil power supply network, 230V/1~/50Hz. The device is equipped with a cable with a Schuko plug.
At first start-up, the device should be subjected to at least the following checks: - check the integrity and stability of the JONIX minimate plus as a whole; - check that all panels and covers are closed and securely fastened;...
6.8 USER INTERFACE AND MENU NAVIGATION JONIX minimate plus device is provided with a touch screen, allowing the user to control device status and to modify its operation as needed.
m i n i m at e p l u s 6.8.2 Switching the device on/off On the main screen, the lower left symbol marked with is used to intuitively identify the status of the device as indicated in the table. DESCRIPTION OF THE GRAPHIC SYMBOL The device is switched ON.
Page 30
m i n i m at e p l u s If the device is pressing will result in Push the "Turn On" button to start confirmation being prompted with this message: the machine or the "Cancel" button to close the window. TURN ON CANCEL If the device is...
m i n i m at e p l u s 6.8.3 Screen lock and settings On the main screen, the upper left symbol marked with is used to intuitively identify the status of the device as indicated in the table. By pressing on the device requests Push the "SCREEN LOCK"...
m i n i m at e p l u s 6.8.4 User login / user logout To make the device settings, it is necessary to log in to the USER, that is, type in the password to be able to use some or all of the functions. The USER LOGIN is always required to: - lock / unlock the screen (paragraph 6.8.3 Screen lock and settings);...
m i n i m at e p l u s 6.8.5 Air ionizing modules screen On the main screen, press the "Ionisers" logo to access the air ionizing modules detail screen: It displays the detailed status of the modules and allows the management of each of them according to the user needs.
m i n i m at e p l u s 6.8.6 Filter ionising module screen On the main screen, press the "Ionisers" logo to access the ionizing modules screen air. Press the arrow> (bottom right) to access the screen with the detail of the filter ionizing module: It displays in detail the status of the module and allows its management...
m i n i m at e p l u s 6.8.7 Filters screen On the main screen, press the "filters" logo to access the filter detail screen: Filters status summary: 10 / 20 / 2030 54 % 1000000000 10 / 20 / 2030 54 % 1000000000 a) Last replacement: shows the last time that the corresponding filter was replaced.
m i n i m at e p l u s 6.8.8 Fan screen On the main screen, press the "fan" logo to access the fan detail screen: Shows a more detailed fan status and allows the management of its operation status as needed.
m i n i m at e p l u s 6.8.9 Settings screen On the main screen, press the "settings" logo to navigate through the modifiable data menus: In each screen it is possible to return to the previous one by pressing Press the "info"...
m i n i m at e p l u s 6.8.9.1 Date and time On the “settings” screen, press the logo to navigate in the corresponding menu and modify the data: a) Date. b) Month. c) Year. d) Hour. e) Minutes.
m i n i m at e p l u s 6.8.9.3 Display brightness On the “settings” screen, press the logo to navigate in the corresponding menu: Press the “+” and “-” keys to change the brightness of the display. 6.8.9.4 Protection On the “settings”...
m i n i m at e p l u s Insert user's password If the password is incorrect, the corresponding message appears. Repeat the operation, entering the correct password. INCORRECT PASSWORD IMPORTANT WARNING The password of the device RXpro is: 100. It is possible to modify the password holding the button c) Change confirmation is required: it only prompts for confirmations of operations without the need for USER LOGIN (paragraph 6.8.4 User login / user logout).
m i n i m at e p l u s When the time zone mode is deactivated, the The time zone mode has been device requests permission to set continuous deactivated. Set the device in operation. continuous operation? Press YES to confirm and NO to turn off the device.
m i n i m at e p l u s h) Copy button: allow to copy the time slots of a day in one Data copy or more different days. Touching the button, a dialog from: box will appear where must be chosen the day from Friday Monday which the slots will be copied and the day in which they...
m i n i m at e p l u s 6.8.9.6.1 Air ionizers maintenance recording Press "Ionisers" to access the corresponding menu: It is used to record the date on which maintenance was carried out on air ionizers. a) Cleaning: records the cleaning operation. b) Replacement: records the replacement operation.
m i n i m at e p l u s 6.8.9.6.2 Filter ioniser maintenance recording Press "Ionisers" to access the corresponding menu: It is used to record the date on which maintenance was carried out on the filter ioniser. a) Cleaning: records the cleaning operation.
m i n i m at e p l u s 6.8.9.6.3 Filter maintenance recording Press "filters" to access the corresponding menu: It is used to record the date on which maintenance was carried out on the filters. a) Filter H14 (or H13). b) Filter F7.
m i n i m at e p l u s 6.8.9.7 Alarms History On the “settings” screen, press the logo to view the history of alarm messages. a) Set the desired time interval to view the alarms. 6.8.9.8 Configuration On the “settings”...
m i n i m at e p l u s 6.8.10 Operation display viewing During normal and correct operation of the device, it is possible to view on the display: The symbol that identifies the spinning fan the symbol that identifies the filter crossed by an arrow. the symbol that identifies the ioniser with an animation to show its operation.
6.8.11 Alarm status notifications On the main screen, notifications appear on the icon of the component that generates an alarm to request intervention by the user or a maintenance technician authorised by JONIX S.p.A.: Filter alarm. Filters Fan alarm.
The frequency of the operations to be performed to ensure proper maintenance of the device JONIX minimate plus depends mainly on the quality of the treated air. Air can be especially harmful for device when it contains polluting or aggressive substances such as:...
7.2.1 Replacing filters The device JONIX minimate plus indicates the need to replace the filters with the icon on the main screen. Replace the filters every time it is notified on the display.
Page 52
m i n i m at e p l u s Fig. 20: Pull the filter locking tabs out and extract the dirty filters. Fig. 21: Put the new / clean filters back in place. Push the filter locking tabs inwards until they click..
m i n i m at e p l u s Fig. 23: Connect the power plug to the mains and switch on the device. Check the operation of the device: the air flow generated by the fan will be perceived. Record the maintenance operation performed using the display as described in paragraph 6.8.9.6 "Recording of maintenance".
7.2.3 Cleaning of ionizing tubes The device JONIX minimate plus indicates the need for maintenance on the ionising pipe with the icon on the main screen. 7.2.3.1 Cleaning of ionizing tubes for air sanitization The JONIX minimate plus device signals the need to clean the ionising pipes per for air sanitation every 7000 hours of operation.
Page 55
m i n i m at e p l u s Fig. 28: Gently unscrew the ionising pipe, gripping it at the base (green part). If the operation is difficult to perform, pull slightly the earthing spring so that it is not in contact with the surface of the tube.
Page 56
m i n i m at e p l u s Fig. 31: Wash the mesh under running hot water and dry it thoroughly with a non-fraying cloth. Do not put back the mesh on the ionising tube if it is even partially wet.
Page 57
m i n i m at e p l u s Fig. 34: Put back the upper filter, making sure the gasket in tire is facing down. Fig. 35: Check that the magnetothermic switches for disconnection of the fan power supply (Q1) and for disconnection of the auxiliary power supply (Q2) are in the ON position.
7.2.3.2 Ionising pipe cleaning for the sanitization of internal components The JONIX minimate plus device signals the need to clean the ionising pipe above the fan every 7000 hours of operation. Clean the ionising tube every time it is shown on the display.
Page 59
m i n i m at e p l u s Fig. 40: Remove the panel that protects the fan by unscrewing the retaining screws Fig. 41: Gently unscrew the ionising pipe, gripping it at the base (green part). If the operation is difficult to perform, pull slightly the earthing spring so that it is not in contact with the surface of the tube.
Page 60
m i n i m at e p l u s Fig. 43: Clean the glass using a damp cloth. Do not use liquid cleaners, sprays, soap or other products. The presence of a whitish layer on the perforated metal sheet inside the glass indicates the need to replace the pipe.
Page 61
m i n i m at e p l u s Fig. 46: Gently screw the ionising tube holding on to the base (green part). If the operation is difficult to perform, pull slightly the earthing spring so that it is not in contact with the surface of the tube.
Page 62
m i n i m at e p l u s Fig. 49: Close the front maintenance access panel with the maintenance access key. Fig. 50: Connect the power plug to the mains. Turn on the device using the light switch.
7.2.4.1 Replacing the ionising tubes for air sanitization The JONIX minimate plus signal the need of replacement of the ionising tubes for air sanitization every 14000 hours of operation. Replace the ionising tubes every time it is shown on the display.
Page 64
m i n i m at e p l u s Fig. 54: Gently unscrew the ionising pipe, gripping it at the base (green part). If the operation is difficult to perform, pull slightly the earthing spring so that it is not in contact with the surface of the tube.
Page 65
m i n i m at e p l u s Fig. 57: Check that the magnetothermic switches for disconnection of the fan power supply (Q1) and for disconnection of the auxiliary power supply (Q2) are in the ON position. Fig.
7.2.4.2 Replacing the ionising tube for the sanitization of internal components The JONIX minimate plus signal the need of replacement of the ionising tube for the sanitization of internal components after 14000 hours of operation. Replace the ionising tube every time it is shown on the display.
Page 67
m i n i m at e p l u s Fig. 62: Remove the panel that protects the fan by unscrewing the retaining screws Fig. 63: Gently unscrew the ionising pipe, gripping it at the base (green part). If the operation is difficult to perform, pull slightly the earthing spring so that it is not in contact with the surface of the tube.
Page 68
m i n i m at e p l u s Fig. 65: Reposition the panel that protects the fan using the retaining screws. Fig. 66: Check that the magnetothermic switches for disconnection of the fan power supply (Q1) and for disconnection of the auxiliary power supply (Q2) are in the ON position.
m i n i m at e p l u s Check the operation of the device, a slight crackling must be heard coming from the ionising pipe and the air flow generated by the fan will be perceived. Record the maintenance operation performed using the display as described in paragraph 6.8.9.6 "Recording of maintenance".
m i n i m at e p l u s - CHECKING OPERATION AND POSSIBLE FAULTS (DIAGNOSTICS) This section summarises the most common problems that may arise when using the unit. Before contacting customer service, perform the checks described in the paragraph on diagnostics and check that there are no alarm signals (paragraph 6.8.11 "Alarm status notifications").
Distributor and always quote the part number and serial number on the plate of the device. Fig. 69: Disconnect the power supply to the device and contact JONIX S.p.A. or a dealer for assistance also when: - the...
9 - DISPOSAL When the JONIX devices are no longer used they must be disposed of in compliance with the regulations in force in the country of installation. The devices consists of the following materials: •...
DICHIARAZIONE CE DI CONFORMITÀ EC DECLARATION OF CONFORMITY EG-KONFORMITÄTSERKLÄRUNG DÉCLARATION CE DE CONFORMITÉ DECLARACIÓN CE DE CONFORMIDAD 2006/42/CE - II A Il Fabbricante JONIX SPA S.B. The Manufacturer Viale Spagna, 31/33 Der Hersteller 35020 Tribano (PD) Le Fabricant ITALY El Fabricante Dichiara che il prodotto Dispositivo di purificazione dell’aria...
Page 74
m i n i m at e p l u s NOTES ..........................................................................................................................................................................................................................................................................................................................................................................................................................74 - 76...
Page 76
JONIX Benefit Corporation Registered Office: Operational Headquarters: Research and Development info@jonixair.com Viale Spagna 31/33 Via dell’Artigianato, 1 Headquarters: Certified mail: jonixsrl@legalmail.it 35020 Tribano (PD) - Italy 35020 San Pietro Viminario Via Tegulaia 10/b Ph. +39 049 9588511 (PD) – Italy...
Need help?
Do you have a question about the minimate plus and is the answer not in the manual?
Questions and answers