Air purification device with advanced cold plasma technology for professional environments (52 pages)
Summary of Contents for Jonix minimate
Page 1
JONIX minimate USE AND MAINTENANCE MANUAL AIR PURIFICATION DEVICE WITH ADVANCED COLD PLASMA TECHNOLOGY MADE IN ITALY...
Page 2
These instructions are translated from Italian (the original language). JONIX srl reserves every right concerning this manual, including the right to make any necessary change or improvement to its products and to the manual at any time and without notice. It is forbidden to reproduce in full or in part this manual...
1.2 - LIABILITY 1.3 - SYMBOLS 2 - WaRnInGs anD GeneRal PRoHIbITIons 3 - THe oPeRaTInG sYsTeM 4 - TecHnIcal DaTa 4.1 - COMPONENT DESCRIPTION JONIX minimate (WhEELED vERSION) 4.1.1 - Technical features JONIX minimate (WhEELED vERSION) 4.2 - COMPONENT DESCRIPTION JONIX minimate (WALL MOUNTED vERSION) 4.2.1 - Technical features JONIX...
Page 4
This manual contains the information and all that is required for the transportation, installation, use and maintenance of the JONIX sanitation and filtering module. minimate Improper installation of the device and/or failure to comply with the instructions in this manual, may invalidate the warranty that the Manufacturer issues for its products.
In particular, if equipment maintenance is carried out in a way that is not in compliance with the instructions supplied, or in a way to jeopardise integrity or modify features, JONIX srl is relieved from any liability inherent to safety of persons and faulty operation of the equipments.
JONIX for another copy or download the document from www.jonixair.com. Repairs and maintenance work must be carried out by JONIX authorised staff or by qualified staff according to the provisions set out by this manual. Do not alter or tamper with the device as it can lead to hazards and the manufacturer of the device shall not be liable for any damage caused.
Page 7
JONIX due to installation, adjustment and maintenance errors or by improper use. Please note that the use of products that require electricity, involves the observance of some...
It is designed for quick and convenient maintenance as all its components can be accessed from the front. Compact, portable and quiet, the JONIX module quickly and effectively meets the minimate requirements of reducing bacterial and particulate load.
J O N I X m i n i m at e 4 - TECHNICAL DATA 4.1 COMPONENT DESCRIPTION JONIX minimate (WHEELED vERSION) 01 Adjustable 2 way air outlet register 08 Prefilter particulate coarse G4 02 Ionising modules JONIX 09 Flat Plug Power Socket Inlets with On/Off Rocker Switch...
J O N I X m i n i m at e 4.2 COMPONENT DESCRIPTION JONIX minimate (WHEElED vERSION) 01 Adjustable 2 way air outlet register 08 Prefilter particulate coarse G4 02 Ionising modules JONIX 09 Flat Plug Power Socket Inlets with On/Off Rocker Switch...
JONIX minimate remain intact until they are assembled. The materials that were not installed for technical requirements are supplied with suitable enclosure secured to the inside or outside of the device itself.
J O N I X m i n i m at e 6 - InsTallaTIon anD coMMIssIonInG aTTenTIon! before carrying out any operation on the devices read all the instructions in this manual carefully. Definitions: UseR: UseR/oPeRaToR: QUalIfIeD sTaff: Person, organisation or Individual been Individuals who have completed a...
- The device has been exposed to the elements. - A malfunction persists despite all the installation and/or maintenance procedures have been performed properly. IMPoRTanT The installer and the user, when using the JONIX device, minimate must take into account and solve all the other types of risk associated with the system.
J O N I X m i n i m at e 6.3 cHoosInG THe InsTallaTIon sITe The packed device is fixed on a pallet with some screws. Once brought to the installation site, it has to be unscrewed from the pallet before proceeding with the installation. Get the appropriate tools to lift and unpack the device.
Page 15
J O N I X m i n i m at e Fig. B: Remove the upper panel with the outer mesh. Fig. C: Remove the two side panels that give access to the pre-punched slots. At this stage it is possible to lift ad fix the device to the wall. aTTenTIon: Due to the size and weight of the device, make sure that for handling a sufficient number of people is available, so that the weight to be loaded by each person is not more than 25 kg in the case of manual handling (in this regard, check...
WaRnInG! Using power supply that does not meet the requirements requested by the device could resolve in damaging the device or part of it. • The electrical mains of the JONIX device must be used for the device only, there minimate must be no other devices powered by the same power line. Do not use adapters, power strips and/or extension cords.
6.6 UsInG THe DeVIce Fig. 01: Connect the device to the mains using the power cable provided. Fig. 02: Once connected to the mains supply, the JONIX module is minimate ready to work. In order to turn on the device act on the red switch 0/I turning it to I.
Lock screen button: it is possible to lock the screen of the JONIX device by minimate clicking on the specific button with a lock on it, placed in the upper left corner of the screen.
Page 19
When the Jonix will notice that the user intervention is needed, this alert state will be shown with the appearance of a notification on the icon of the device part that has caused the alarm.
J O N I X m i n i m at e 6.8.2 ionisers screen It displays the detailed status of the modules and allows the management of each of them according to the user needs. a) on/off button: it turns on/ off the corresponding module.
J O N I X m i n i m at e 6.8.5 settings screen It shows all the sets of parameters of the device. 6.8.5.1 date and time Date and time can be setted by touching the buttons “+” and “-“. 6.8.5.2 Language The user can set the language of the text on the diplay from this screen.
(green tick) to confirm the password, or the cancel button (red cross) to cancel the operation. the password of the device JONIX is: 100 minimate It is possible to modify the password holding the button to the side of the currently set password.
Page 23
4 time slots. f) start time: start time of the time slot. g) minimate: enable / disable JONIX minimate h) modules a - B: enable / disable the ionising module (A - B).
J O N I X m i n i m at e 6.8.5.6 maintenance Maintenance screens of the ionising modules and of the filters are accesible from this screen. a) Access to the menu "Ionisers Maintenance". b) Access to the menu "Filters Maintenance". ionisers maintenance Allows to record the date when a maintenance operation was done on the ionising modules (A - B).
J O N I X m i n i m at e 6.8.5.7 alarms History Shows the list of all the alarm messages displayed from the device in the set time lapse. 6.8.5.8 configuration a) advanced configuration: restricted menu technical support, accessible to the final user.
Page 26
The frequency of the operations to be performed to ensure proper maintenance of the device depends mainly on the quality of the treated air. JONIX minimate Air can be especially harmful for condensers when it contains polluting or aggressive substances such as:...
Page 27
J O N I X m i n i m at e 7.2.1 cleaning the Ionising Tubes clean the ionising tubes every time it is shown on the display. Fig. 03: Switch the device off by turning the luminous On/Off switch to o. Remove the plug connected to the mains.
Page 28
J O N I X m i n i m at e Fig. 06: Pull off the outer mesh from the tube if you have not already done so in the previous point. If this is difficult to do, turn the mesh around the glass while pulling to remove it.
Page 29
J O N I X m i n i m at e Fig. 10: Gently screw the ionising tube holding on to the base (green part). If the operation is difficult to perform, pull slightly the earthing spring so that it is not in contact with the surface of the tube.
Page 30
J O N I X m i n i m at e Register the maintenance operation done using the display: Reset the alarm launched by the device in the alarm screen: Make sure the condensers work properly: you must be able to hear a slight hissing. Check that the device responds to commands.
Page 31
14000 hours of operation. - filters: the components have the function of barrier, and they tend to saturate so that eventually they will obstruct the air flow. The detection devices internal to JONIX signal how minimate necessary is an operation of replacement in order to maintain a smooth functioning of the device.
Page 32
J O N I X m i n i m at e Fig. 14: Gently unscrew the tubes, using the green plastic base. If you have trouble, first pull off the outer mesh. Fig. 15: Screw delicately the ionising tube holding on to the base (green part).
Page 33
J O N I X m i n i m at e Register the maintenance operation done using the display: Reset the alarm launched by the device in the alarm screen: Make sure the condensers work properly: you must be able to hear a slight hissing. Check that the device responds to commands.
Page 34
J O N I X m i n i m at e 7.3.2 Replacing filters Replace the ionising tubes every time it is notified on the display. Fig. 17: Switch the device off by turning the luminous On/Off switch to o. Fig.
Page 35
J O N I X m i n i m at e Fig. 20: Put the new / clean filters back in place. Push the filter locking tabs towards the device until they click. Fig. 21: Close the anterior panel. Switch the device on by turning the On/Off switch to I.
Page 36
J O N I X m i n i m at e Reset the alarm launched by the device in the alarm screen: 8 - OPERATIONAL CHECK AND TROUBLESHOOTING This section summarises the most common problems that may arise when using the unit. Before contacting customer services, carry out the checks listed below.
Page 37
J O N I X m i n i m at e 9 - DIsPosal When JONIX devices are no longer used they must be disposed of in compliance with minimate the regulations in force in the country of installation. The unit consists of the following materials: • Stainless steel.
Page 38
4. The purchaser has the right to benefit from the 12 month warranty only if the warranty certificate is filled in correctly in all parts and sent within 10 days of purchase to: JONIX S.r.l., viale Spagna, 31/33 – 35020 Tribano (PD) Italy 5. The warranty is only valid if the system is purchased from an authorised retailer.
Page 39
EU DECLARATION OF CONFORMITY EC DECLARATION OF CONFORMITY JONIX S.R.L. LEGAL SITE Viale Spagna, 31/33 – 35020 Tribano (PD) SCIENTIFIC SITE Via Tegulaia 10/b - 56121 Pisa OPERATIVE SITE Via Romagnoli, 12/A - 40010 Bentivoglio (BO)
Page 40
J O N I X m i n i m at e ATTACHMENTS EXPLODED JONIX minimate (WHEELED vERSION) HF70000871 HF11000663 HF17019158 HF03000680 HF70000866 HF03000681 HF40000090 HF03000593 HF03000679 HF17019159 HF17019160 71KITIONMM HF03000595 HF03000678 HF03000601 HF17019155 HF03000611 HF70000865 HF55000255 HF03000596 HF70000882 HF03000594...
Page 41
J O N I X m i n i m at e EXPLODED JONIX minimate (WALL MOuNTED vERSION) HF70000871 HF17019380 HF03000680 HF17000866 HF03000681 HF40000090 HF03000593 HF03000679 HF17019159 71KITIONMM HF03000595 HF03000678 HF03000601 HF17019379 HF03000611 HF70000865 HF11000663 HF55000255 HF03000596 HF70000882 HF03000594 HF03000600...
Page 42
J O N I X m i n i m at e OvERALL DIMENSIONS JONIX minimate (WHEELED vERSION) : ambient air. : ionised air flow.
Page 43
J O N I X m i n i m at e OvERALL DIMENSIONS JONIX minimate (WALL MOuNTED vERSION) : ambient air. : ionised air flow.
Need help?
Do you have a question about the minimate and is the answer not in the manual?
Questions and answers