Warns of a hazard resulting from electric voltage which can lead to injuries. Caution! Warns of a hazard which can lead to damage to property. The current version of the operating manual can be found at: www.trotec.de Operating Manual – Air Cleaner TAC 1500 / TAC 3000...
Fig. 1 Front and side view Operating element carrying handle air outlet feet (TAC 1500) or rollers (TAC 3000) control panel power cable air inlet operating hours counter Operating Manual – Air Cleaner TAC 1500 / TAC 3000...
When the device is not being used, observe the following storage conditions: • dry, • protected from dust and direct sunlight, • with a plastic cover to protect it from invasive dust, if neces- sary. Operating Manual – Air Cleaner TAC 1500 / TAC 3000...
Fig. 5 Connection diagram of pressure sensor hoses in the standard arrangement 1-2- 3 a + A b + B 1-3- 2 a + B b + C Fig. 3 Connection diagram of pressure sensor hoses in the cleanroom arrangement Operating Manual – Air Cleaner TAC 1500 / TAC 3000...
Page 6
• to connect the pressure sensor hoses correctly. Insert frame Bag filter Pre-filter Filterbox 1 Ventilator F i l t e r b o x 2 Fig. 6 b) Bag filter arrangement – wiring Operating Manual – Air Cleaner TAC 1500 / TAC 3000...
7.6 m of air hose each can • Prior to operation you have to ensure that the filters have be connected to both the TAC 1500's air inlet and outlet. been installed in the device as desired.
Page 8
• With the filter arrangement G4, F7 and H13 to meet the re- quirements of dust class H, the TAC 1500 with connected ex- haust air hose (7.6 m, laid in 2 90° arcs) reaches an air flow rate of 600 m³/h (TAC 3000 = 1150 m³/h).
It may be necessary to remove the earth cable from the and the fan housing. side panels. 10. Mount the side panel. Make sure that the side panels are grounded. Fig. 14 Earth cable of the side panel Operating Manual – Air Cleaner TAC 1500 / TAC 3000...
When the device warns of a spent pre-filter and/or HEPA filter, still a flow rate of 500 m³/h is ensured. For an effective filtration of pollutants the scheduled directives of the (German) employer's liability insurance association recommend to exchange the filter. Operating Manual – Air Cleaner TAC 1500 / TAC 3000...
Air transport hose Tronect SP-T, Article number Article number length 7.6 m 6.100.001.200 6.100.001.205 Professional extension cable, Article number Article number length 20 m, 230 V / 2.5 mm² 7.333.000.376 7.333.000.376 Operating Manual – Air Cleaner TAC 1500 / TAC 3000...
Need help?
Do you have a question about the TAC 1500 and is the answer not in the manual?
Questions and answers