Launch
10.2.2 Base plate layout
TLT235SC(U) symmetric installation is shown in Fig.9a,,
TLT235SC、TLT240SC symmetric installation is shown in
Fig. 9b, TLT235SB、TLT240SB symmetric installation is
shown in Fig.9c:
With total width (A) as the basis, draw two parallel
1#
70mm
(2.76in)
1#
70mm
(2.76in)
TLT235、TLT240 Economical Two-post User's Manual
Entrance
Fig. 8
A
3392mm(133.54in)
2582mm(101.65in)
C
2792mm(109.92in)
Fig.9a
3420mm(134.65in)
2610mm(102.76in)
2820mm(111.02in)
Fig.9b
16
lines (#1 and #2) on the concrete slab, with the error
within 3mm.
Determine the power side column location on any
chalk line, and mark the total width (B) of the base
plate. Mark the points 3 and 4.
Starting from point 3, draw one diagonal line
(C) ,forming a triangle. In this way, the vertical lines
can determine the location of the two columns.
A
C
Diagonal 3443mm (135.55in)
2#
3
4
2#
3
4