Technical Data; Replacement Parts; Ec Declaration Of Conformity - Lincoln LMC 1 User Manual

Table of Contents

Advertisement

User Manual
LMC 1
LMC 1 multi controller
Dimensions (L x W x H) ............................ 200 x 120 x 90 mm
Display ............................................ 4-fold 7-segment display
Operating temperature .................................... - 10 to + 70 °C
Storage temperature ....................................... - 40 to + 85 °C
Inputs:
Number .............................. 8, short-circuit proof, non-floating
Cutoff frequency .......................................................... 100 Hz
Outputs:
Number ................................................ 5, overload protected
.......4 relay outputs NO contacts 6A, 0-240 VAC/ VDC
...................1 electronic output 24 VDC/10A or 230 VAC/3A
Reverse polarity protection:
Operating voltage inputs are protected against reverse
polarity
Residual ripple at operating voltage:
.................................................. ±5% according to DIN 41755
NOTE
If the internal fuses need to be replaced,
use only the original type.
6001a02
Protection and monitoring:
Current limitation ..................... Sustained short-circuit proof
Overload protected ........................................................ yes
Idle protected ................................................................. yes
Power failure backup time ...................... > 15 ms at 230 VAC
Protection class ........................................................... IP 54
LMC 1 multi controller
Type 24 VDC ..................................................... 236-10567-1
Declaration of Conformity according to EMC-directive 2004/104/EC
We hereby declare that the multi controller
Lincoln Multi Controller LMC 1
in the design we have delivered complies with the regulations
in the above-referenced directive.
The following harmonized standards were applied:
DIN EN 60204
Safety Test
DIN EN 61000-6-4
Emitted Interference
DIN EN 61000-6-2
Interference Immunity
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259

Technical data

AC input
Input voltage ......................... 230 VAC ±10% ; 50/60 Hz ±5%
Fast fuse .................................................... 4 A/250 V internal
DC input
Input voltage .................................................... 24 VDC ±20%
Slow fuse ........................................................................ 10 A
Safety DIN EN 60204
Protection class ........................................................ Class I
EMC
Interference suppression VDE 0875 T 11, EN 55011 Class A
Noise output ................................ according to EN 61000-6-4
Immunity to electrical noise ......... according to EN 61000-6-2
6001a02

Replacement parts

Type 230 VAC ................................................... 236-10567-2
Walldorf, 05-May-06, Dr. Ing. Z. Paluncic
9.3EN-98001-A07
NOTE
The noise output complies with the
requirements for the industrial sector. If
used in residential areas, this can lead to
interaction under certain circumstances.