Installation; Connection - Lincoln LMC 1 User Manual

Table of Contents

Advertisement

User Manual
LMC 1

Connection

Fig. 3
LMC 1 electrical connections
Fig. 4
Housing
Fig. 5
Connection diagram
Page 8 of 36
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259

Installation

The terminals for signal inputs (pos. 5), for the
ACTUATOR lines (pos. 6) and for the mains supply
(pos. 7) are located on the control p.c.b. (Fig. 3).
5 -
Signal input
- for 3-wire initiators up to 24 V (PNP)
- for 2-wire initiators, residual voltage < 5 V
6 -
Control output (ACTUATOR)
- 4 relay outputs
- 1 electronic output
7 -
Voltage supply (24 VDC / 10 A or 230 VAC / 3 A)
6609m06
8 -
Program interface (RJ 45)
Route the LMC 1 connection cables through the cable
glands (item 9 and 10) on the bottom of the housing.
Possible tensile forces on the cables have to be relieved
from outside of the housing.
Fasten on the rear of the housing using the mounting
channels (pos. 11) with the cable glands towards bottom
(wall-mounting).
Cable glands:
9 -
Voltage supply (M16 screwed connection)
10 -
Control inputs and outputs (for 0.5 mm² cable)
6607m07
11 -
Mounting channels for fastening (dimensions see page 36)
A-
Programming
B-
BUS interface, option (field bus plug)
C -
Controller
D -
Display
I1 - I8 Signal input connection
6610b06
Q1-Q5 Control output (ACTUATOR) connection
9.3EN-98001-A07