COBRA chain-lubrication systems, continued

Operation

Commissioning

Fig. 32
Operating panel
a -
"UP" key
b -
"DOWN" key
NOTE
"RESET" as halt function:
You can interrupt the running lubrication
time by pressing the "RESET" key
(> 2 sec.). The next pause cycle starts from
6001a02
the beginning.
NOTE
„RUN" to trigger additional lubrications:
You can interrupt the running pause cycle
by pressing the "RUN" key (> 2 sec.). The
lubricating time starts from the beginning.
6001a02
NOTE
As soon as you press the "UP" key (pos. a,
Fig. 32) outside of the configuration mode,
the actual rest of the expired pause cycle is
shown in the display.
6001a02
Page 30 of 36
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
Parameter default
6001a02
Selecting the lubrication system
First switch SW1 to SW3 to "0-0-1"
(OFF-OFF-ON).
6613m06
Then set the right-hand DIP switch (SW4) to ON (Fig. 33).
Fig. 33
DIP switch: COBRA chain-lubrication systems - settings
After that, switch SW4 back to OFF (Fig. 34).
Fig. 34
DIP switch:
COBRA chain-lubrication systems – operating mode
The standard settings to control your COBRA chain-
lubrication system are now complete and the system is ready
for operation.
Please refer to page 31 for possible parameter adaptations.
9.3EN-98001-A07
NOTE
No parameter defaults can be set for
COBRA chain-lubrication systems.
The standard setting "0" applies.
6662b06
6662c06