Parameter Defaults - Lincoln LMC 1 User Manual

Table of Contents

Advertisement

User Manual
LMC 1
Operation
Commissioning
Fig. 37
DIP switch – configuration mode
Fig. 38
Operating panel
a -
"UP" key
b -
"DOWN" key
NOTE
"RESET" as hold function:
You can interrupt the running lubrication
time by pressing the "RESET" key
(> 2 sec.). The pause time starts from the
6001a02
beginning.
NOTE
„RUN" to trigger additional lubrications:
You can interrupt the running pause time
by pressing the "RUN" key (> 2 sec.). The
lubricating time starts from the beginning.
6001a02
NOTE
As soon as you press the "UP" key (pos. a,
Fig. 38) outside of the configuration mode,
the actual rest of the expired pause time is
shown in the display.
6001a02
Page 34 of 36
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
Spray lubrication systems, continued
6668b06
6613m06
Parameter default
Set the DIP switches (see view Fig. 2, page 6) as shown
in Fig. 37:
"1-1-1-0" (SW1 ON - SW2 ON - SW3 ON - SW4 OFF)
Select from the following versions to set the parameter
defaults in your spray lubrication system:
- no metering device, no cycle counter, clock-pulsed .... 0
- with metering device, no cycle counter, clock-pulsed .. 1
- with metering device and cycle counter, clock-pulsed .2
- no metering dev., no cycle counter, not clock-pulsed .. 3
- with metering dev., no cycle counter, not clock-pulsed 4
- with metering dev. and cycle counter, not clock-pulsed 5
NOTE
The version number setting (0 - 5) is
shown in the LMC 1 display and is made
using the UP & DOWN keys on the
operating panel (see pos. a & b, Fig. 38).
6001a02
Complete your selection (0 - 2) with the ENTER key
(Fig. 38).
If you do not acknowledge your selection with ENTER, the
standard value of "0" is automatically set.
Selecting the lubrication system
First switch SW1 to SW3 to "1-0-1"
(ON-OFF-ON).
Then set the right-hand DIP switch (SW4) to ON (Fig. 39).
Fig. 39
DIP switch: Spray lubrication systems - settings
After that, switch SW4 back to OFF (Fig. 40).
Fig. 40
DIP switch: Spray lubrication systems – ready for operation
The standard settings to control your spray lubrication system
are now complete and the system is ready for operation.
Please refer to page 35 for possible parameter adaptations.