LH70 Initial setup (Example)
Display unit: LH70-1 (1 axis input)
Measuring unit
SJ700A (1 axis)
Output resolution: 5μm
SJ700A
START
Set to basic setting mode
When the power is turned
on for the first time after
shipment from the factory
Connect the AC adapter and
Turn on the primary power supply
(Not
key)
AC primary power source
For LH70-1, LH70-2
Power ON
About 2 sec
When the display is
once.
The display will be
( If you want to change the destination, press
When you have made your selection, press
Setting conditions
Basic
settings
Detailed
X axis
settings
When you want to change
the basic settings
AC adapter is energized.
Turn on
key,
the LED light changes
from "blinking" to "off" and then
Press and hold
key
for 3 seconds.
The following display appears
, press the
key on the right side
. (Destination selection mode)
key. )
to save your settings.
LH70 Initial setup (Example)
The detailed settings are the factory default settings.
Setting items
TYPE
ADD(Addition display)
Destination
Measuring unit
resolution
Display resolution*
and polarity
Display switching
Axis label
Compensation value
Flicker control
Sleep
* The initial value is the measurement unit resolution set in the basic settings.
Press
key once.
The display will be
Press
key to check the current measurement unit resolution.
If the resolution is not 5μm, press
After checking the resolution, press
Input 1
Switch from basic settings to normal count mode.
Press
key once and the display will change to
Press
key once and the display will change to
Press
key once to automatically switch to advanced settings mode.
The display will be
Confirm that the display is
(Press
key to change the polarity)
When the selection is complete, press
When you press
This completes the initial settings
Setting value (selection)
1 axis model is not displayed
1 axis model is not displayed
default
STD
5μm
5μm
default
Input 1:
default
Display: X
No setting(OFF)
default
Strong (2)
default
No setting(OFF)
default
. (Measurement unit resolution)
key to change it.
key to save the settings.
Confirm that the resolution of input 1
is 5 μm (SJ700A scale).
* 10 μm "10U" for Digiruler PL20C
. Press
key once.
display.
key to save the settings.
key, the display becomes the normal display.
Finished
Ver.1 (2021.1) CS&S
.
.
1/3

Advertisement

loading

Summary of Contents for Magnescale LH70

  • Page 1 Ver.1 (2021.1) CS&S LH70 Initial setup (Example) Display unit: LH70-1 (1 axis input) Setting conditions The detailed settings are the factory default settings. Setting items Setting value (selection) TYPE 1 axis model is not displayed ADD(Addition display) 1 axis model is not displayed...
  • Page 2 Ver.1 (2021.1) CS&S Display unit: LH70-2 (2 axes input) Setting conditions The detailed settings are the factory default settings. Setting items Setting value (selection) TYPE 2 axes model is not displayed ADD(Addition display) 2 axes model is not displayed Basic...
  • Page 3 Ver.1 (2021.1) CS&S Display unit: LH70-3 (3 axes input) Setting conditions The detailed settings are the factory default settings. Setting items Setting value (selection) TYPE GENERAL (General machine ) ADD(Addition display) Not displayed when GENERAL is selected Basic settings Destination default 5μm...

This manual is also suitable for:

Lh70-1Lh70-2Lh70-3