Magnescale LG20 Quick Start Manual
Hide thumbs Also See for LG20:

Advertisement

Quick Links

LG20 Initial setup (Example)
Display unit: LG20-1 (1 axis input)
Measuring unit
SJ700A (1 axis)
Output resolution: 5μm
SJ700A
START
Set to basic setting mode
When the power is turned
on for the first time after
shipment from the factory
Connect the AC adapter and
Turn on the primary power supply
(Not
key)
AC primary power source
For LG20-1, LG20-2
Power ON
About 2 sec
When the display is
once.
The display will be
( If you want to change the destination, press
When you have made your selection, press
Setting conditions
Basic
settings
Detailed
settings
X axis
When you want to change
the basic settings
AC adapter is energized.
Turn on
key,
the LED light changes
from "blinking" to "off" and then
Press and hold
key
for 3 seconds.
The following display appears
, press the
key on the right side
. (Destination selection mode)
key. )
to save your settings.
LG20 Initial setup (Example)
The detailed settings are the factory default settings.
Setting items
Destination
Measuring unit
resolution
Display resolution*
and polarity
Display switching
Axis label
Compensation value
Flicker control
Sleep
* The initial value is the measurement unit resolution set in the basic settings.
Press
key once.
The display will be
Press
key to check the current measurement unit resolution.
If the resolution is not 5μm, press
After checking the resolution, press
Input 1
Switch from basic settings to normal count mode.
Press
key once and the display will change to
Press
key once and the display will change to
Press
key once to automatically switch to advanced settings mode.
The display will be
Confirm that the display is
(Press
key to change the polarity)
When the selection is complete, press
When you press
This completes the initial settings
Setting value (selection)
STD
default
5μm
5μm
default
Input 1:
Display:X
default
No setting(OFF)
default
Strong (2)
default
No setting(OFF)
default
. (Measurement unit resolution)
key to change it.
key to save the settings.
Confirm that the resolution of input 1
is 5 μm (SJ700A scale).
* 10 μm "10U" for Digiruler PL20C
. Press
key once.
display.
key to save the settings.
key, the display becomes the normal display.
Finished
Ver.1 (2021.1) CS&S
.
.
1/3

Advertisement

loading

Summary of Contents for Magnescale LG20

  • Page 1 Ver.1 (2021.1) CS&S LG20 Initial setup (Example) Display unit: LG20-1 (1 axis input) Setting conditions The detailed settings are the factory default settings. Setting items Setting value (selection) Basic Destination default settings 5μm Measuring unit resolution 5μm Display resolution* Measuring unit...
  • Page 2 Ver.1 (2021.1) CS&S Display unit: LG20-2 (2 axes input) Setting conditions The detailed settings are the factory default settings. Setting items Setting value (selection) Basic Destination default settings 5μm Measuring unit resolution 5μm Display resolution* and polarity Measuring unit SJ700A (2 axes)
  • Page 3 Ver.1 (2021.1) CS&S Display unit: LG20-3 (3 axes input) Setting conditions The detailed settings are the factory default settings. Setting items Setting value (selection) Basic Destination default settings 5μm Measuring unit resolution Measuring unit 5μm Display resolution* and polarity SJ700A (3 axes) Output resolution: 5μm...