Magnescale LG20 Initial Setup Manual

Magnescale LG20 Initial Setup Manual

Digital counter
Hide thumbs Also See for LG20:

Advertisement

Quick Links

LG20
Initial Setup Manual
START
Check the conditions of use
Table of contents
Preparations before making the initial settings (checking conditions of use)
How to set up Basic Settings
How to set up Detailed Settings (continued from Basic Settings)
Factory Default (All Clear)
Appendix 1: Front panel, Alarm indication
Appendix 2: Adapter connections (scales and gauges)
INITIAL SETUP FLOW
Advance
Preparation
Settings
STEP 1~3
Contents
LG20 initial Setup Manual
Basic
Detailed
Settings
STEP 4~5
STEP 1~3
STEP 4~5
Ver.1 (2020.11) CS&S
LG20
Finished
Page
2 to 3
4 to 6
7
9
10
11 to 12
1/12

Advertisement

loading

Summary of Contents for Magnescale LG20

  • Page 1 4 to 6 STEP 1~3 How to set up Detailed Settings (continued from Basic Settings) STEP 4~5 Factory Default (All Clear) Appendix 1: Front panel, Alarm indication Appendix 2: Adapter connections (scales and gauges) 11 to 12 1/12 LG20 initial Setup Manual...
  • Page 2 SZ70-1 SR128 / SR127 0.5μm CH01-LW**C SZ51-MS01 + SZ70-1 DL310B/330B 10μm DZ-51 SZ70-1 SR138R(GB-ER) 0.5μm CH04-03C DK series 0.1μm or CE29-** 0.5μm * For adapter information, refer to Appendix 2 Adapter Connection in this Manual 2/12 LG20 initial Setup Manual...
  • Page 3 Upper:X Axis label Display axis label selection Upper axis: "X" or "Z" Middle:Y Middle axis: "Y" or "Z" NOTE: Can be used with LG20-1 and LG20-2. Compensation Settings of linear compensation and Err OFF:off segmented error compensation value Lin Err:linear compensation ±600μm/m...
  • Page 4 COUNTRY (destination country): Sets the output resolution of the scale to be Please select your region connected. Supports the input of length and angle display units. COUNTRY (Destination) Symbol Destination Unit General area U.S.A. Japan 4/12 LG20 initial Setup Manual...
  • Page 5 JAPAN 1μm 25μm Display method: - For each setting item, the current setting contents are displayed after about 1 second. If there is no change in the contents, move to the next section with key. 5/12 LG20 initial Setup Manual...
  • Page 6 The display will be ⑤ Press key. The display returns to normal. This completes the basic settings. Key to be used at the end of the basic settings mode (LG20) Reset key Φ lamp (two times display) Select axis key...
  • Page 7 The axis labels for the 1st and 2nd axes can be selected from "X", "Y", and "Z". NOTE LG20-1, LG20-2 LABEL Axis label NOTE: Can be used with LG20-1 and LG20-2. Error Setting Selection of error compensation function Compensation value default Linear compensation...
  • Page 8 5 min. 30 min. 1 min. 10 min. Step 5 6. When the Detailed Settings are complete, switch to the normal display. Press key. This completes the initial settings.. 8/12 LG20 initial Setup Manual...
  • Page 9 ⓐ 3. Pressing the Blindfold key changes the display as shown below. → → → START → → → completion 4. Turn off the primary power supply of the AC adapter. 9/12 LG20 initial Setup Manual...
  • Page 10 Status Display Status (Blinking) Storage data error Measurement unit not connected Speed over (NOTE) Overflow Power failure NOTE: When using an adapter connection (SZ**), no speed override indication is shown, but rather an error message. 10/12 LG20 initial Setup Manual...
  • Page 11 Scale Resolution Adapter Counter SR-1711(GP)、SR10A/741(GS)、 0.5μm SZ05-T01 LG20 SR50A(GF,GF-R)、SR30A(GM)、 LH70/71/71A/72 SR801/801R(GL) LY71/72 Screws * HA13A, 15A, 23A and 25A are used as head amps SZ05-T01 Head-amp Connector Screws Use screws to secure it in place. 11/12 LG20 initial Setup Manual...
  • Page 12 Head-amp Connector Screws Use screws to secure it in place. Gauge Resolution Adapter Counter DE12BR/30BR 0.1μm SZ70-1 LG20 LH70/71/71A/72 Counter unit LY71/72 Cable (300mm) Screws Head-amp Use screws to secure it in place. Connector SZ70-1 12/12 LG20 initial Setup Manual...