Good Read LED Duration

This feature specifies the amount of time that the Good Read LED remains on following
a good read. The good read LED on time can be set within a range of 100 milliseconds
to 25.5 seconds (0.1 to 25.5 seconds) in 100ms increments.
Follow these instructions to set this feature:
1. Determine the desired setting in milliseconds. A setting of 0 means that the good
2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program-
4. Scan the barcode: SELECT GOOD READ LED DURATION SETTING.
5. Scan the appropriate three digits from the keypad in
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program-
This completes the procedure. See
Table 3. Good Read LED Duration Setting Examples
STEP
ACTION
1
Desired Setting
Divide by 100 (and pad with
2
leading zeroes)
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT LABEL GONE TIMEOUT SETTING
Scan Three Characters From
5
Appendix E, Keypad
6
Scan ENTER/EXIT PROGRAMMING MODE
Product Reference Guide
read LED stays on until the next time the trigger is pulled.
with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020,
etc.
ming Mode.
ing the duration which was determined in the steps above. You will hear a two-
beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.
NOTE
ming Mode.
Good Read LED
stays on until next
trigger pull (000)
000
'0', '0' and '0'
Table 3
for some examples of how to set this feature.
EXAMPLES
200ms
1500ms
002
015
'0', '0' and '2'
'0', '1' and '5'
LED and Beeper Indicators
Appendix E, Keypad
represent-
2500ms (2.50 sec.)
025
'0', '2' and '5'
29