Password Loss; Cooling System Failure; Software Loading Failure - H3C F5030 Manual

Hide thumbs Also See for F5030:
Table of Contents

Advertisement

NOTE:
For information about serial port parameter setting, see

Password loss

For more information about dealing with the console port password loss, see the release notes for
the firewall.

Cooling system failure

Symptom
The temperature of the firewall is higher than the normal operating temperature (45°C or 113°F).
Solution
To solve the issue:
1.
Verify that the fan trays are operating correctly.
2.
Verify that the operating environment of the firewall has good ventilation.
3.
If the following alarm information is generated, the temperature of the firewall has reached the
warning-level high temperature alarm threshold,
Jul 6 11:16:15:872 2020 H3C DEV/4/TEMPERATURE_WARNING: -Context=1; Temp
erature is greater than the high-temperature warning threshold on slot
1 sensor inflow 1. Current temperature is 74 degrees centigrade.
Use the
firewall keeps rising. If the temperature has reached the alarming-level high temperature alarm
threshold, back up data immediately, power off the firewall, and contact your local sales agent.
Information about the firewall temperature in the
varies by firewall model.
4.
If the issue persists, contact your local sales agent.

Software loading failure

Symptom
Software loading fails and the system runs the software of the previous version.
Solution
To solve the issue:
1.
Verify that the physical ports are correctly connected.
2.
Verify that no parameter is configured incorrectly during the loading process. You can examine
the software loading process displayed on the HyperTerminal for configuration errors. The
following errors can lead to software loading failure.
When XMODEM is used to load software, a baud rate other than 9600 bps is selected, but
the baud rate for the HyperTerminal is not reset.
When TFTP is used to load software, an incorrect IP address, software name, or TFTP
serve path is configured.
When FTP is used to load software, an incorrect IP address, software name, username, or
password is entered.
display environment
"Logging in from the console
command to examine whether the temperature of the
display environment
6-37
port."
command output

Advertisement

Table of Contents
loading

This manual is also suitable for:

F5060F5080F5030-dF5060-dF5080-dF5000-m ... Show all

Table of Contents