Kenmore W10884766A Installation Instructions Manual page 18

Table of Contents

Advertisement

Available languages

Available languages

3. Remove plastic cover from gas pressure regulator cap.
4. Turn gas pressure regulator cap counterclockwise with
5
/
" (1.6 cm) combination wrench to remove.
8
NOTE: Do not remove the spring beneath the cap.
A
B
C
A. Plastic cover
B. Gas pressure regulator cap with hollow end facing out
C. Gas pressure regulator cap with solid end facing out
D. Washer
E. Gas pressure regulator cap
5. Turn over the gas pressure regulator cap and reinstall
on regulator so that the solid end faces out and the
marking "ê NG" is facing the direction shown in the
above drawing.
6. Replace plastic cover over gas pressure regulator cap.
To Convert Surface Burners (LP Gas to Natural Gas)
1. Remove burner cap.
2. Remove the burner base.
A
A. Igniter electrode
B. Burner cap
C. Gas tube opening
D. Burner base
3. Apply masking tape to the end of a
to help hold the gas orifice spud in the nut driver while
changing it. Press nut driver down onto the gas orifice spud
and remove by turning it counterclockwise and lifting out.
Set gas orifice spud aside.
B
A
C
A. Igniter electrode
B. Orifice spud
C. Orifice spud holder
D. Screws
18
Side view before
D
E
Side view after
B
C
D
9
/
" (7 mm) nut driver
32
D
4. Gas orifice spuds are stamped with a number on the side.
Replace the LP gas orifice spud with the correct Natural
gas orifice spud.
A. Stamped number
Refer to the following chart for the correct Natural gas
orifice spud placement.
Natural Gas Orifice Spud Chart
Burner Rating
Color
19,000 BTU (ST) White/Gray
18,000 BTU
Blue
17,000 BTU (ST)
N/A
17,000 BTU
White/Blue
9,200 BTU
White/Black
8,000 BTU
White/Yellow
5,000 BTU
White/Orange 1.00
1,200 BTU
Black
NOTE: Refer to the model/serial/rating plate located on the
oven frame behind the top left-hand side of the oven door for
proper sizing of spuds for each burner location.
5. Place LP gas orifice spuds in the orifice spud bag.
IMPORTANT: Keep the LP gas orifice spuds in case
of reinstallation with LP gas.
6. Replace the burner base.
7. Replace burner cap.
8. Repeat steps 1 through 7 for the remaining burners.
To Convert Oven Bake Burner (LP Gas
to Natural Gas)
1. Remove the oven racks and the oven door. See the "Oven
Door" section.
2. Remove 2 screws and washers at the rear of the oven
bottom.
3. Lift the rear of the oven bottom up and back until the front
of the panel is away from the front frame. Remove from
oven and set it aside on a covered surface.
A. Screws
B. Oven bottom
A
Size (mm) ID Number
1.84
184
1.94
194
1.75
175
1.90
190
1.35
135
1.25
125
100
0.52
52
A
B

Advertisement

Table of Contents
loading

Table of Contents