IMPORTANT: READ PRIOR TO STARTING THIS EQUIPMENT

1.0 INSTALLATION

1.1 Location
A.
For typical placement in a compressed air system, see
drawing.
B.
Air compressor intake–Locate air compressor so that
contaminants potentially harmful to the dryer (e.g.
ammonia) are not drawn into the air system.
C.
Dryer should be installed in a moderately heated, well
ventilated area. Avoid locations immediately adjacent to
cold exterior windows or walls, or adjacent to high
temperature ovens or boilers.
D.
Clearances: Free air flow
Models 1000 to 1500:
Front 24 inches (610 mm)
Back 36 inches (915 mm)
Sides 24 inches (610 mm)
Top 36 inches (915 mm)
Models 1750 to 3000
Front 24 inches (610 mm)
Back 36 inches (915 mm)
Sides 24 inches (610 mm)
Top 36 inches (915 mm)
Service - To facilitate maintenance leave 24 inches
(610 mm) of clearance in front of dryer.
E.
Standard units are designed to operate in ambients:
Air-cooled: 45 to 110°F (7 to 43°C).
Water-cooled: 45 to 130°F (7 to 54°C).
F.
Dryer is designed to operate at all altitudes - no adjust-
ment for altitude is required.
G.
The installation of a flexible connection prior to the dryer
is recommended to prevent possible damage from
vibration.
NOTE: Outdoor installation–Standard units are designed for
indoor installation. Contact manufacturer if installing
outdoors.
Condenser
Air Outlet
Water Outlet
Water Inlet
Air Inlet
See Exploded
View "A"
OUT
Door Locks
IN
BACK VIEW
Compressor
Manual Drain
Valve (Optional
)
Automatic Drain
Valve (Optional
)
Manual
Drain Valve
Automatic
Drain Valve
Control
Panel
Quick
Release
Electric
Demand
Drain (EDD)
FRONT VIEW
Aftercooler
Dryer
Separator
EXPLODED VIEW "A"
DRAIN VALVE CONNECTIONS
Electrical
Entry
Moisture
Separator
(single stage)
3-way Valve
for Manual
Draining
Optional
Oil Removal
Filter (2 stage)
RS232
Port
3