IMPORTANT: READ PRIOR TO STARTING THIS EQUIPMENT

1.0 INSTALLATION

1.1 Location

A.
For typical placement in a compressed air system, see
drawing.
B.
Air compressor intake – Locate air compressor so that
contaminants potentially harmful to the dryer (e.g. ammo-
nia) are not drawn into the air system.
C. Free Air Flow Clearances
Front: 36 inches (914 mm)
Back: 6 inches (152 mm)
Sides: 36 inches (914 mm)
Service - To facilitate maintenance leave 36 inches
(914 mm) of clearance in front of dryer.
D. Standard units are designed to operate in ambients:
Air-cooled: 40 to 110°F (4 to 43°C).
Water-cooled: 40 to 130°F (4 to 54°C).
E. Installations in altitudes above 4500 feet (1370 meters)
– Dryer is adjusted to operate in altitudes up to 4500 feet
(1370 meters). If dryer is installed in an altitude above
this, and has not been preset at the factory for this altitude,
contact manufacturer's Service Department.
There shall be no external forces or vibrations
transmitted to the dryer inlet/outlet connections from the piping.
External piping must be properly supported. The installation of
a flexible connection or vibration dampener, within the air/gas
stream, prior to the dryer is recommended to further reduce the
possibility of damage from vibration or pulsations. Failure to do
so may void the warranty.
NOTE: Outdoor installation – Standard units are designed for
in door installation. Contact manufacturer if installing outdoors.
Control Panel
Moisture Separator
RHP130 and RHP200
2
Air Inlet
Air Outlet
230-VAC Electrical Entry
120-VAC Electrical Cord
Drain Outlet
Condenser
Electric Timed Drain
w/3-Way Valve
(Standard)
Models
Aftercooler
Compressor
Control Panel
Moisture Separator
Electric Timed Drain Assembly
w/3-Way Valve
RHP300, RHP500, RHP750, and RHP1000
Dryer
Oil Removal
Separator
Filter
Air Inlet
Air Outlet
Primary Electrical Entry
Secondary Electrical Entry
Condenser
Drain Outlet for RHP1000
on rear panel.
Drain Outlet
Models: RHP300 Through RHP750 Only
Water Outlet Connection
Models: RHP300 Through RHP1000
(W/C Models Only)
Water Inlet Connection
Models: RHP300 Through RHP1000
(W/C Models Only)
Models