ENGINEERING DATA

MINIMUM - MAXIMUM OPERATING CONDITIONS
Min.-Max. Inlet Air Pressure (compressed air at inlet to dryer)
Max. Inlet Air Temperature (compressed air at inlet to dryer)
Min.-Max. Ambient Temperature
REFRIGERATION SYSTEM DATA
Compressor Type
Refrigeration Compressor Horsepower
BTU/HR - Refrigeration Only @ 38°F PDP & 100°F Ambient
Outlet Air Temperature (nominal at rated conditions)
Refrigerant Type
Refrigerant Charge
Suction Pressure Setting
Compressor Control Ranges (psig) (out-in)
Condenser Fan Switch Setting (in-out)(psig)
(air-cooled models)
Air Flow Across Condenser (cfm) (air-cooled models)
Condenser Cooling Water Requirements (water-cooled models)
Recommended Water Pressure (psig)
Gallons Per Minute of Flow Required with 85°F Cooling Water
Inlet Water Connections
ELECTRICAL
Nominal Voltage
Max.- Min. voltage
Rated Load Amps**
Locked Rotor Amps**
Minimum Circuit Ampacity
Branch Circuit Fuse Size (amps)
Watts @ 35°F Evaporator & 100°F Ambient
Resistance (ohms)
Nominal Voltage
Max. - Min. Voltage
Rated Load Amps**
Locked Rotor Amps**
Minimum Circuit Ampacity
Branch Circuit Fuse Size (amps)
Watts @ 35°F Evaporator & 100°F Ambient
Resistance (ohms)
Nominal Voltage
Max. - Min. Voltage
Rated Load Amps**
Locked Rotor Amps**
Minimum Circuit Ampacity
Branch Circuit Fuse Size (amps)
Watts @ 35°F Evaporator & 100°F Ambient
Resistance (ohms)
Nominal Voltage
Max. - Min. Voltage
Rated Load Amps**
Locked Rotor Amps**
Minimum Circuit Ampacity
Branch Circuit Fuse Size (amps)
Watts @ 35°F Evaporator & 100°F Ambient
Resistance (ohms)
* Allows continued operation with some restriction in the water strainer
** Compressor(s) only, air-cooled only
† For 208-230 ratings are for 230V input, for 380-420 ratings are for 400V input
1000
Air-cooled
Water-cooled
6
60 HZ
47,060
50 Hz
39,217
High
Low
Fan 1
Fan 2
60/50 Hz
2800/2330
60/50 Hz
15.1/12.6
3/4"
23.9
156
37.9
60
8,480
Three phase (Total) (+/- 7%)
0.501
9.3
70
15.6
20
8,480
Three phase (Total) (+/- 7%)
2.27
7.9
54
13.8
20
8,480
Three phase (Total) (+/- 7%)
3.56
9.3
70
16.1
25
6,220
Three phase (Total) (+/- 7%)
2.27
1250
1500
1750
30-200 psig (2.1-14 kgf/cm
120°F (49°C)
45°F (7°C) - 110°F (43°C)
45°F (7°C) - 130°F (54°C)
Hermetic - Non-cycling
7.5
9
10
60,650
70,590
84,915
50,542
58,825
70,763
85°F (29°C)
R-404A
See dryer serial number tag
(electric hot gas by-pass valve requires no adjustment)
450-348
47-64
300-230
325-255
4700/3920
4700/3920
4700/3920
40 min. - 120 Max*
18.7/15.6
24.4/20.3
25.5/21.2
1"
208-230/3/60
253-187
26
31.7
33.6
172
253
253
40.5
47.6
50
60
70
80
9,860
12,140
12,780
0.412
0.31
0.27
460/3/60
506-414
11
13.8
14.9
90
118
118
17.7
21.2
22.6
25
35
35
9,860
12,140
12,780
1.69
1.13-1.36
1.13-1.29
575/3/60
632-518
9
10.9
12.2
62.3
96.5
96.5
15.3
17.5
19.2
20
25
30
9,860
12,140
12,780
2.54-2.87
1.76-2.02
1.76-2.02
380-420/3/50
462-342
11
13.8
14.9
90
118
118
18.1
21.6
22.9
25
35
35
7,210
8,820
9,280
1.69
1.13-1.36
1.13-1.29
2000
2500
3000
2
)
12
15
17.5
94,120
121,300
141,180
78,433
101,083
117,650
5600/4670
9400/7835
11,200/9335
32.2/26.4
40.7/33.9
44.2/36.8
1-1/4"
52.9
62.2
59.6
350
376
425
74.1
92.5
89.7
125
150
125
18,960
22,100
25,640
0.22
0.158-0.18
0.412 & 0.27
25
27.6
25.9
158
178
208
35.4
42.5
40.2
60
70
60
18,960
22,100
25,640
0.83
0.686-0.798
1.69&1.13-1.29
20
22.1
21.2
125
143
158.8
29.3
35.2
34
45
50
50
18,960
22,100
25,640
1.28
1.07-1.30
2.54-2.87
&1.76-2.02
25
27.1
25.9
151
174
208
35.7
42.2
40.8
60
60
60
10,800
14,600
16,490
0.83
0.686-0.798
1.69&1.13-1.29
13