Rheem RHMV3021SNACJA Design & Technical Manual page 7

Duct type
Hide thumbs Also See for RHMV3021SNACJA:
Table of Contents

Advertisement

Type
Model name
Cooling
Operation range
Heating
NOTES:
• Specifications are based on the following conditions:
– Cooling: Indoor temperature of 80 °FDB/67 °FWB (26.67 °CDB/19.44 °CWB), and outdoor temperature of 95 °FDB/75 °FWB (35 °CDB/23.9 °CWB).
– Heating: Indoor temperature of 70 °FDB/59 °FWB (21.11 °CDB/15 °CWB), and outdoor temperature of 47 °FDB/43 °FWB (8.33 °CDB/6.11 °CWB).
– Pipe length: 24 ft 7 in (7.5 m), Height difference: 0 ft (0 m). (Between outdoor unit and indoor unit.)
– Standard static pressure: 0.18 in.WG (45 Pa): 24 model, 0.23 in.WG (58 Pa): 30, and 36 model, 0.28 in.WG (70 Pa): 48 model
• Protective function might work when using it outside the operation range.
• *1: Maximum current:
– The maximum value when operated within the operation range.
– The total current of indoor unit and outdoor unit.
• *2: Sound pressure level:
– Measured values in manufacturer's anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
RHMV2421MNACJA RHMV3021SNACJA RHMV3621MNACJA RHMV4821SNACJA
°F (°C)
%RH
80 or less
°F (°C)
- 3 -
Duct
Inverter heat pump
64 to 90 (18 to 32)
80 or less
60 to 86 (16 to 30)
1. Specifications

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents