General Description Of S-Series - Air Burners 300 Series Operating Manual

Self-contained refractory walled air curtain burner
Table of Contents

Advertisement

S300 Refractory Walled Air Curtain Burner with HATZ 4H50TIC Diesel Engine
OPERATING MANUAL
GENERAL DESCRIPTION S-SERIES
The self-contained refractory walled air curtain system is manufactured as an over-the-
road transportable combustion system designed to reduce clean wood waste and veg-
etative growth to ash in a safe, controlled burning process without excessive particu-
late emissions. The FireBox is open to the ground, except for the Roll-off versions; they
have a floor to accommodate the roll-off rail system.
The standard S-Series machines are offered in several sizes. The smallest is the
S116 (16 ft. firebox) and the largest is the S330 (30 ft. firebox). The table below shows
the approximate dimensions.
Overall Size
Model
L x W x H
S330
40' 4" x 11' 10" x 9' 6"
S327
37' 4" x 11' 10" x 9' 6"
S223
33' 3" x 8' 6" x 8' 6"
S220
30' 1" x 8' 6" x 8' 6"
S119
27' 3" x 7' 2" x 7' 4"
S119R**
27' 6" x 7' 2" x 8' 3"
S116
24 7"' x 7' 2" x 7' 4"
S116R**
24' 11" x 7' 2" x 8' 3"
T24
19' 8" × 7' 8" × 5' 8"
* Approximate values. Achievable through-put depends on nature of waste stream and other factors.
** Cable-hoist version; Hook-lift version is 5" shorter
Diesel Engine Version:
Drive System:
Electric Motor Version:
Options:
*) Fuel Consumption:
**) Through-Put:
NOTES:
Above-Ground Air Curtain Burner Dimensions
L x W x H
30' 2" x 8' 5" x 8' 1"
27' 2" x 8' 5" x 8' 1"
22' 11" x 6' 2" x 7' 1"
19' 8" x 6' 2" x 7' 1"
19 x 5' x 6'
19 x 5' x 6'
16' x 5' x 6'
16' x 5' x 6'
12' × 4' × 4'
S330 & S327: HATZ 4H50TIC (Tier 4 Final) or equivalent engine.
S223, S220, S-119 & S-116: HATZ 3H50TIC (Tier 4 Final) or equivalent engine.
PTO & mechanical direct coupling drive.
Motor: 3-Phase, heavy-duty, with enclosed pre-programmed variable frequency speed controller
(VFD); Power in: Three Phase 480V, 50Hz or 60Hz, or selected other voltages;
Drive System: Direct drive.
Ash clean-out rake - price will be quoted for plain faceplate (S300) or universal quick disconnect
(S200 & S100); Steel floor: Ember screen (S200 & S100 only); Rough-terrain removable dolly.
Indicated fuel consumption rates approximated.
Through-put depends on many factors, such as nature and type of wood waste, its moisture
content, prescribed opacity limits, operator skills, elevation of location, etc. The figures stated
here are guidelines only. If more specific information is required, please contact the Factory.
All weights and dimension are approximate.
Dimensional drawings can be provided on request.
Subject to change without notice.
Page 2 of 29
FireBox
Weight
lbs.
59,000
54,600
40,250
36,650
30,100
39,900
27,500
36,300
9,983
Average
Fuel
Thru-put*
gal/hr.
tons/hr.
3.0
11-13
3.0
9-11
2.0
7-9
2.0
5-7
1.9
3-5
1.9
3-5
1.9
2-4
1.9
2-4
0.35
½-1
(Vers.02.02.2021)