OPERATING MANUAL
THERMO-CERAMIC PATCHING COMPOUND
For minor repair of S-Series refractory panels and doors.
NOTE: This is an air cured product, reseal unused portion immediately.
1) Cracking of the panels is normal as they flex in the heat. Filling the cracks
every 6 months or as needed will extend the life of your Thermo-Ceramic
Panels.
2) Air Burners patching compound is pre-mixed and ready to use (may require
some stirring).
3) Storage: Compound should be stored indoors in a frost free location.
4) Preparation: The area in and around the damaged area to be patched must
be cleaned and brushed to provide the best surface for the compound to ad-
here. Remove all loose refractory and debris from the area to be patched.
5) Wet the cleaned surface with a light spray or damp cloth.
6) Installation: Using a trowel or similar tool, pack the refractory compound ma-
terial into cracks and into areas where the refractory is missing. To achieve
proper thickness, trim off the excess material using a sharp flat blade or the
side of the trowel.
7) Allow the material to harden overnight before placing the FireBox back into
service. After the compound has hardened operate the FireBox under nor-
mal conditions.
Contact Air Burners, Inc., should you require assistance with
this maintenance tasks. Send Email to support@airburners.com,
Air Burners Part # 6900-1003
Thermo-Ceramic Wet Pre-Mix