OPERATING MANUAL
HOW TO SET UP THE MACHINE (MBW Panel)
C) STARTING
PRE-CHECKS
1. Check all belts and fluids.
2. Make sure PTO (clutch) is disengaged (the
lever in the LEFT position).
Note:
The key can only be removed from the key switch in
the OFF position. Turning the key left to the Auto
position is not functional and is not used for your
HATZ engine.
STARTING Engine
1. Turn key switch right to ON (1) position. The dis-
play will be activated.
2. Wait for automatic PREHEAT to complete.
3. Turn key to START, release, once engine is run-
ning.
4. Wait for speed to level off at 900 RPM (Idle).
5. Press Throttle Button UP, wait for speed to level
off at 1400 RPM (Engage Clutch).
6. Engage PTO now by pushing lever RIGHT until it
snaps into place.
7. Press Throttle Button UP again to set speed at
2200 (S-327) or 2300 (S-330) RPM
(Operating Low).
8. Press Throttle Button UP again to set speed at
2400 (S-327) or 2500 (S-330) RPM
(Operating High).
WARNING:
Your HATZ Diesel Engine is an EPA Tier 4 FINAL certified
computer controlled engine. Do not attempt to re-program the ECM by
pressing buttons at random on the control panel. Contact Air Burners Cus-
tomer Support Department for help, if any errors have occurred.
Call 772-220-7303. Note: The engine does not require DEF.