S300 Refractory Walled Air Curtain Burner with HATZ 4H50TIC Diesel Engine
OPERATING MANUAL
HOW TO SET UP THE MACHINE (Murphy Panel)
SHUT-DOWN
SHUT-DOWN WARNING:
Do not switch off engine with
PTO engaged. This can cause
serious damage to driveline.
1. Press Throttle DOWN BUTTON (lower 2nd
from right). From Operating High first wait for
speed to level off at Operating Low.
2. From Operating Low press Throttle DOWN
BUTTON and wait for speed to level off at
1400 RPM (Cool Down).
3. Disengage PTO now by pushing lever LEFT.
4. Press Throttle DOWN BUTTON again
and wait for speed to level off at 900
RPM (Idle).
5. Turn key to OFF (O) position.
RUNNING
Engine RPM's (air-fan speed) is prepro-
grammed and fixed at positions Idle, Cool
Down, Operating Low and Operating High.
WARNING:
Your HATZ Diesel Engine is an
EPA Tier 4 FINAL certified com-
puter controlled engine.
Do not attempt to re-program the
ECM by pressing buttons at ran-
dom on the control panel. Contact
Air Burners Customer Support De-
partment for help, if any errors
have occurred.
Call 772-220-7303
The engine does not require DEF.
Engine Compartment & Controls
Page 12 of 29
Fuel Tank - Open Side Door
Clutch Handle
(Layout May Vary)