1. SEE FIGURE 8-5 FOR RECOMMENDED AWG CONDUCTOR SIZES.
2. CUSTOMER SUPPLIED AC (ALTERNATING CURRENT) INPUT POWER CONNECTIONS SHOULD BE MADE AT TERMINALS TB6-44, TB6-46 AND TB6-48. FOR CUSTOMER SUPPLIED DC (DIRECT CURRENT) POWER,
THE RED AND BLACK WIRES FROM THE POWER SUPPLY BOARD SHOULD BE REMOVED AND THE CUSTOMER POWER CONNECTIONS SHOULD BE MADE AT TERMINALS TB5-42 AND TB5-43.
3. IN THE 'JUMPER OFF' POSITION, THE JUMPER CAN BE COMPLETELY REMOVED OR STORED ON A SINGLE PIN. IN THE 'JUMPER ON' POSITION, THE JUMPER IS INSTALLED ACROSS BOTH PINS TO PROVIDE
CONTINUITY.
4. WITH UNIT ON AND NO ALARMS, THERE SHOULD BE CONTINUITY BETWEEN TERMINALS TB4-39 AND TB4-41. CONTACTS ARE RATED AT 5 AMPS.
5. STANDARD PRESSURE MODELS 4100 & 5400 ONLY. HIGH PRESSURE MODELS 40 THROUGH 450 ONLY.
ENCLOSURE
INTERIOR
J3
J1
J4
J2
JP1
JP8
1 2
4
9
10
3
5
6
7
8
TB1
RIGHT_BTM_THERM
RIGHT_TOP_THERM
LEFT_BTM_THERM
LEFT_TOP_THERM
REMOTE START / STOP
JUMPER
JUMPER
4
OFF
ON
150 PSIG
250 PSIG
LEFT TOWER PRESSURE SWITCH
NO
YES
--
--
4
--
--
--
--
RIGHT TOWER PRESSURE SWITCH
ACTIVATED BY DRYER
DEFAULT
FAULT ALARM ONLY
--
--
--
--
Point-to-Point Diagram – Energy Savings Controller