Dryer MOP
ISO Class
Dew Point
Cycle Time (minutes)
Time
t0
t1
t2
t3
t4
t5
t6
t7
t8
Purge time (min:sec)
[(t3-t2) or (t7-t6)]
Repress. time (min:sec)
[(t4-t3) or (t8-t7)]
NOTE: When operated in the Demand Mode, drying times t4-t0 and t8-t4 can extend to a maximum of 30 minutes each. Purge times in the
Demand Mode, regardless of the ISO Class selection, will always be equal to the purge times of the ISO Class 2 (10 min.) Fixed Cycle (3:54 for
150 psig MOP and 2:54 for 250 psig MOP).
60 - 150 psig (4.1 - 10.3 barg)
1
2
-73°C
-40°C
-20°C
-100°F
-40°F
-4°F
4
10
Time from start of cycle
(minutes : seconds)
00:00
00:00
00:00
00:02
00:02
00:02
00:06
00:06
00:06
01:12
04:00
06:55
02:00
05:00
08:00
02:02
05:02
08:02
02:06
05:06
08:06
03:12
09:00
14:55
04:00
10:00
16:00
Reference Data
01:06
03:54
06:49
00:48
01:00
01:05
Fixed Cycle Timing – Energy Savings Controller
— 41 —
3
4
1
+3°C
-73°C
+38°F
-100°F
16
24
4
00:00
00:00
00:02
00:02
00:06
00:06
10:50
00:48
12:00
02:00
12:02
02:02
12:06
02:06
22:50
02:48
24:00
04:00
10:44
00:42
01:10
01:12
Table 8-3
120 - 250 psig (8.3 - 17.2 barg)
2
3
-40°C
-20°C
-40°F
-4°F
10
16
Time from start of cycle
(minutes : seconds)
00:00
00:00
00:02
00:02
00:06
00:06
03:00
05:40
05:00
08:00
05:02
08:02
05:06
08:06
08:00
13:40
10:00
16:00
02:54
05:34
02:00
02:20
4
+3°C
+38°F
24
00:00
00:02
00:06
09:20
12:00
12:02
12:06
21:20
24:00
09:14
02:40

Hide quick links: