Open emitter wiring
Only one output can be connected as an open emitter, since the load is on pin 6. The other outputs cannot be
used anymore.

7.5 RS-232 wiring

The IDS NXT rome has a serial interface of the type RS-232:
·
Baud rate: 300 ... 230 400 Baud
·
Input voltage: max. ±15 V
·
Output voltage: -5,7 V to +6.2 V
·
Data rate: max. 250 kbps
·
Compatible with TIA/EIA-232-F standard
·
Permissible range according to RS-232 from ±3 V to ±15 V
2021-11-08
Fig. 7: Wiring as open emitter
IDS NXT: Technical manual IDS NXT rome