How To Fill The Pump Housing With Water; Control Panel - UPRENT impulse MUMBAI IP Series User Manual

Table of Contents

Advertisement

4.1

How to fill the pump housing with water

1. .Make shore all draining valves are closed.
2. Fill fully stone catcher with water, through suction side connector it is easier do connecting D100
F/M 90 degree connector (1)
4.2

Control panel

Impulse Mumbai is supplied with a star-delta switch, it has three
positions: Neutral (1), Star (2) and Delta (3).
WARNING
Turning the switch too slowly will cause the motor's thermal protection to trip. Return
the switch to the neutral position and switch it on again.
:
11