11.2 Removal Procedure of Outdoor Unit

Steps
1. Remove big handle,valve cover and top cover
Remove the screw connecting the big handle and
right side plate, and then remove the big handle.
Remove the screw connecting the valve cover and
right side plate, and then remove the valve cover.
2.Remove top panel
Remove the screws connecting the top
panel with the front panel and left&right
side plate, and then remove the top panel.
3.Remove front side panel
Loosen the screws connecting the front side
panel and chassis. Remove the front side
panel.