13
Fuse Holder
I
Refrigerators equipped with a vent fan(s) include an inline fuse on the wire supplying power to the fans(s).
This wire is connected to the 12 VDC terminal block supplying DC power to the refrigerator controls.
➤ Disconnect 12 VDC power.
➤ Open the fuse holder.
➤ Replace the fuse using a 3 A fuse.
➤ Screw the fuse holder back together.
➤ Reconnect 12 VDC power.