Download Print this page
HANYOUNG NUX MP3 Instruction Manual

HANYOUNG NUX MP3 Instruction Manual

Digital multi panelmeter

Advertisement

Quick Links

Digital Multi Panelmeter
MP3/MP6
INSTRUCTION MANUAL
Thank you for purchasing HANYOUNG NUX CO,.Ltd. Product.
Please check whether the prouduct you purchased is the
exactly same as you ordered. Before using product, please
read instruction maunal carefully.
Safety Information
Before you use, read safety precautions carefully, and use this product properly.
The precautions described in this manual contain important contents related
with safety; therefore, please follow the instructions accordingly. The
precautions are composed of DANGER, WARNING and CAUTION.
DANGER
There is a danger of occurring electric shock in the input/output terminals so
please never let your body or conductive substance is touched.
WARNING
1. This product does not contain an electric switch or fuse, so the user needs
to install a separate electric switch or fuse externally. (Fuse rating: 250V
0.5A)
2. To prevent defection or malfunction of this product, supply proper power
voltage in accordance with the rating.
3. To prevent electric shock or malfunction of product, do not supply the power
until the wiring is completed.
4. Since this product is not designed with explosion-protective structure, do not
use it any place with flammable or explosive gas.
5. Do not decompose, modify, revise or repair this product. This may be a
cause of malfunction, electric shock or fire.
6. Reassemble this product while the power is OFF. Otherwise, it may be a
cause of malfunction or electric shock.
7. If you use the product with methods other than specified by the
manufacturer, there may be bodily injuries or property damages.
8. Due to the danger of electric shock, use this product installed onto a panel
while an electric current is applied.
CAUTION
1. The contents of this manual may be changed without prior notification.
2. Before using the product you purchased, make sure that it is exactly what
you ordered.
3. Make sure that there is no damage or abnormality of the product during
delivery.
4. Do not use this product at any place with corrosive (especially noxious gas
or ammonia) or flammable gas.
5. Do not use this product at any place with direct vibration or impact.
6. Do not use this product at any place with liquid, oil, medical substances,
dust, salt or iron contents. (Use at Pollution level 1 or 2)
7. Do not polish this product with substances such as alcohol or benzene.
8. Do not use this product at any place with a large inductive difficulty or
occurring static electricity or magnetic noise.
9. Do not use this product at any place with possible thermal accumulation due
to direct sunlight or heat radiation.
10. Install this product at place under 2,000m in altitude.
11. When the product gets wet, the inspection is essential because there is a
danger of electric leakage or fire.
12. If there is excessive noise from the power supply, using insulating
transformer or noise filter is recommended. The noise filter must be
attached to a panel which is already connected to a ground and the wire
between the filter output and power supply terminal must be as short as
possible.
13.If puttig power cables closely together then It is effective against noise.
14.Do not connect anything to the unused terminals.
15.After checking the polarity of terminal, connect wires at the correct position.
16.When this product is connected to a panel, use a circuit breaker or switch
approved with IEC947-1 or IEC947-3.
17.Install the circuit breaker or switch at near place for convenient use.
18.Write down on a label that if the circuit breaker or switch is operating then
the power will be disconnected since the circuit breaker or switch is installed.
19.For the continuous and safe use of this product, the periodical maintenance
is recommended.
20.Some parts of this product have limited life span, and others are changed by
their usage.
21.The warranty period for this product including parts is one year if this product
is properly used.
1381-3, Juan-Dong, Nam-Gu Incheon, Korea
HEAD OFFICE
TEL: (82-32)876-4697 FAX : (82-32)876-4696
Suffix Code Structure
Suffix code
Model Name
MP
3
Aspect
Dimension
6
Displayable
4
5
Digits
DV
DA
Measurement
AV
Input
AA
Specification
AVR
AAR
N
0
1
2
3
4
Output
5
Specification
6
(Option)
7
8
9
10
11
A
B
Type
C
Current Output about PV (present value)
Output Specification, 0 ~ 11, is "OPTION."
The specification of this manual may be changed without a prior notification due to its
improvement
When measuring a current higher than 5 A d.c, an exclusive shunt will be necessary so
please choose "Type of DC Volt" when you are ordering.
Communication output and BCD output are on the development.
Ratings
100 - 240 V a.c 50 - 60 Hz allowable operating
Power Supply
voltage range : 85 ~ 110 %
5 VA
Power Consumption
7 segment LED Display
Display
Insulation Resistance
100
2000 V a.c min. for 1 minute between external terminal and case
Dielectric Strength
By noise simulator, square-shaped wave noise, pulse
Noise Immunity
width 1
Malfunction : 10 - 55
each direction for 1 hour
Vibration Resistance
Durability : 10 - 55
each direction for 2 hours
Malfunction : 100 m/s
Shock Resistance
Durability : 300 m/s
-10 ~ +55
Operating Ambient temperature
Relative Humidity 35 ~ 85 % RH
Operating Ambient Humidity
With no corrosive gas
Operating Circumstance
-20 ~ 65
Storage Ambient Temperature
Mechanical: 20,000,000 ps Min.
Relay Life Expectancy
Electrical: 100,000 ps Min.
Approx. 180 g
Net Weight
MF0101E090305
Description
Aspect 96 x 48 mm
Aspect 72 x 36 mm
4 digits (9999)
5 digits (99999)
d.c VOLT
d.c AMPERE
a.c VOLT
a.c AMPERE
a.c VOLT(RMS)
a.c AMPERE(RMS)
Display only
Relay Output(HI,GO,LO) + Current Output(4 - 20 mA)
Relay Output (HI, GO, LO)
NPN Open Collector Output(HI,GO,LO), BCD Output(Static)
PNP Open Collector Output(HI,GO,LO), BCD Output(Static)
NPN Open Collector Output(HI,GO,LO),
CurrenOutput(4 - 20 mA)
PNP Open Collector Output(HI,GO,LO),
Current Output(4 - 20 mA)
NPN Open Collector Output(HI,GO,LO), Serial Output(lowspeed)
PNP Open Collector Output(HI,GO,LO), Serial Output(lowspeed)
NPN Open Collector Output(HI,GO,LO), RS485 Output
PNP Open Collector Output(HI,GO,LO), RS485 Output
BCD Output
Relay Output (HI,GO,LO) +RS485 Front
Front case: Acrylic type
Front case: Plate type
24 V d.c power supply (only for plastic type)
min. (at 500 V d.c) between external terminal and case
,
1000 V
Single amplitude 0.5
Single amplitude 0.75
2
for 3 times each in X Y Z direction
2
for 3 times each in X Y Z direction
(with no freezing)
(with no freezing)
X Y Z
X Y Z

Advertisement

loading

Summary of Contents for HANYOUNG NUX MP3

  • Page 1 MF0101E090305 Digital Multi Panelmeter MP3/MP6 INSTRUCTION MANUAL Thank you for purchasing HANYOUNG NUX CO,.Ltd. Product. Please check whether the prouduct you purchased is the exactly same as you ordered. Before using product, please 1381-3, Juan-Dong, Nam-Gu Incheon, Korea HEAD OFFICE read instruction maunal carefully.
  • Page 2: Wiring Diagram

    : 100 ms 12 - 24 V d.c 50 mA Max. Sampling Cycle a.c type : 300 ms (MP3 A, B Type) -1999 ~ 9999 (4 digits) Max. Displayable Digits Display function of converting to a value from measured...
  • Page 3: Factory Default

    Factory Default MP6-4- -0-B MP6-4- -1-B (Relay Output + Current Output 4 - 20 mA) (Relay Output ) MP3-DA MP3-AV MP3-AA MP3-DV MODE PARAMETER MP6-4- -2-B MP6-4- -3-B (NPN TR Output) (PNP TR Output) PARAMETER MP6-4- -4-B (NPN TR Output)
  • Page 4 Parameter 1 Terminology Explanation Comparative Output Mode (PSot) : Set a range of input specification of desired to be measured. : Use a function of desiring to multiply an input measured value. Display Output Operation Explanation : Correct an error by adding/subtracting to an input measured value. Ex) If you want to display 5000 but the measured value is 5010, then set -10 in parameter.
  • Page 5: Parameter Setting Method

    Parameter Setting Method BCD Dynamic Output (Auxiliary Logic) Parameter 1 ( key - more than 2 seconds) Wiring diagram Decimal Point POL : Polarity DPX : Decimal point 0.05V 500V To enter the setting mode of parameter 1, press and hold key for more than 2 seconds in RUN MODE.
  • Page 6 How to Set Slope If you want to display 3600(min -1999 ~ 9999) then the model specification should be MP3-4-DV-X and an input should be 10V. The way of changing the parameter setting is written the below (Follow the steps 1 ~ 4).

This manual is also suitable for:

Mp6