How to change Setting of Parameters
1.In RUN MODE, press
for more than 2 seconds to enter Parameter 1
setting mode or for less than 2 seconds to enter Parameter 2.
2.By using
,
keys, you can see one of the parameters in each parameter
1 or 2. If you are at one of the parameters, the parameter and set value is
flickering repeatedly in the display.
3.By using
key, you can begin with changing a setting value in the chosen
parameter.Only the setting value in the chosen parameter is flickering after
pressing key.(When the default is 0, the number is flickering with only 0
To begin the
Default
setting then
Ex)
value:
press
When the set number is 0, the number is flickering with only 0
To change 100
th
digit, press
key for 3 times. Each time you press
then the position of digit will move to the left side by one. The chosen placed digit
is flickering.
When the set number is 0, the number is flickering with only 0
By pressing
key, you can go back to parameter mode if you are done with
the setting. Again, the parameter and the set value are flickering repeatedly. To
go back to RUN MODE, you need to press
How to Set Slope
If you want to display 3600(min -1999 ~ 9999) then the model specification
should be MP3-4-DV-X and an input should be 10V. The way of changing the
parameter setting is written the below (Follow the steps 1 ~ 4).
1.By pressing
key for more than 2 seconds, enter Parameter 1 mode.
2.In
(Input Range) parameter, set
3.In
(scale high limit) parameter, set
keys.
4.In
(scale low limit) parameter, set
shift, up and down keys. Set the above and press
Menu key again to go back to RUN MODE.
PARAMETER 1
Parameter
Set Value
Defaulting Set Values
While pressing
key, press the key
will be displayed. At that time, press
will be defaulted. ( If
defaulted)
Error Display Code
: This will be displayed when it is higher than Max Range 9999 (for 4
digits model) or a negative number is appeared in Normal mode.
Normal mode : SCH 0 or SCL 0
: This will be displayed when a measured input value is over max input
range.
: A setting error will be displayed when a setting value of High
Comparative Output is less that that of Low Comparative Output.
Retransmission Function (Auxiliary Output)
RS485 Communication
By assigning Address from 00 to 99 and by selecting modulation speed of
Serial Transmission it is possible to transmit.
Retransmission Speed (BPS) Selection Setting: (1200, 2400, 4800, 9600,
19200, 38400)
Serial Communication
Having a present displayed value generates signals of POL (polarity), DOT
(decimal point), CK (CLOCK), DATA and LATCH in order to be easily done
with connecting PLC and other processors.
Current Output
Generate 4 - 20 mA d.c for a present displayed value. (resolution 4.096)
BCD Output
Generate a present displayed value as BCD type (D0, D1, D2, D3, POL
(polarity) DOT (decimal point), A0, A1, A2, A3)
PNP Output (Open Collector Output 12 - 24 V d.c below 50 mA)
NPN Output (Open Collector Output 12 - 24 V d.c below 50 mA)
RELAY Output (250 V a.c below 5A) 1a, 1b 3
Select other values
Default:
by pressing
key
th
digit.
th
digit.
key.
range mode.
by using shift, up and down
Display value
by using
3600
1800
0
5 V
Input value
then
key again then all the set values
function is ON, it is impossible to be
Dimension & Panel cutout
MP3
th
digit.)
key
key
10 V
MP6
Unit : mm