Download Print this page
HANYOUNG NUX BA1 Instruction Manual

HANYOUNG NUX BA1 Instruction Manual

Digital panelmeter

Advertisement

Quick Links

Digital panelmeter
BA1
INSTRUCTION MANUAL
Thank you for purchasing HANYOUNG product.
Please check whether the product is the exactly same as you ordered.
Before using the product, please read this instruction manual carefully.
Please keep this manual where you can view at any time
Safety information
Before using the product, please read the safety information thoroughly and use it properly.Alerts
declared in the manual are classified to Danger, Warning and Caution by their criticality
DANGER indicates an imminently hazardous situation
DANGER
which, if not avoided, will result in death or serious injury
WARNING indicates a potentially hazardous situation
WARNING
which, if not avoided, could result in death or serious
injury
CAUTION indicates a potentially hazardous situation
CAUTION
which, if not avoided, may result in minor or moderate
injury
DANGER
Do not touch or contact the input/output terminals because it may
cause electric shock.
WARNING
• I f the user use the product with methods other than specified by the manufacturer, there
may be bodily injuries or property damages.
• T o prevent electric shock or equipment failure, please do not turn on the power until
completing wiring.
• N ever disassemble, modify, or repair the product. There is a possibility of a malfunction,
an electric shock, or a risk of fire.
• P lease turn off the power when mounting/dismounting of the product. This is a cause of
an electric shock, a malfunction, or failure.
• T o prevent damage or failure of this product, please supply the rated power voltage.
• S ince this is not explosion-proof structure, please do not use in a place where
combustible or explosive gas is around.
• S ince there is a possibility of an electric shock, please use the product as mounted on a
panel while the power is being supplied.
CAUTION
• T he contents of the instruction manual are subjective to change without prior notice.
• P lease make sure that the specification is the same as what you have ordered.
• P lease make sure that the product is not damaged during shipping.
• P lease use this product in a place where corrosive gas (such as harmful gas, ammonia,
etc.) and flammable gas do not occur.
• P lease use this product in a place where there is no direct vibration and a large physical
impact to the product.
• P lease use this product in a place where there is no water, oil, chemicals, steam, dust,
salt, iron or others (Contamination class 1 or 2).
• P lease do not wipe this product with organic solvents such as alcohol, benzene and
others. (Please use mild detergent)
• P lease avoid places where excessive amounts of inductive interference and electrostatic
and magnetic noise occur.
• P lease avoid places where heat accumulation occurs due to direct sunlight or radiant heat.
• P lease use this product in a place where the elevation is below 2,000 m.
• P lease make sure to inspect the product if exposed to water since there is a possibility of
an electric leakage or a risk of fire.
• I t is effective against noise if making the power lines of the product the twisted pair wiring.
• P lease do not connect anything to the unused terminals.
• P lease connect wires properly after making sure the polarity of terminal.
• P lease install a switch or break near the operator to facilitate its operation.
• W rite down on a label that the operation of circuit breaker or switch disconnects the power
since the devise is installed.
• I n order to use this product properly and safely, we recommend periodic maintenance.
• S ome parts of this product have limited expected life span and aged deterioration.
• T he warranty of this product (including accessories) is 1 year only when it is used for the
purpose it was intended under normal condition.
Suffix code
Model
Code
BA1-
-
-
Output
N
10
20
Input
D
11
21
Range code
1~8
Power supply voltage
Description
ini DC indicator 48(W) × 24(H) ㎜
instruction only
DC voltage (voltmeter)
DC current (ammeter)
DC voltmeter (1 - 5 V DC)
DC ammeter (4 - 20 ㎃ DC)
Refer to the measurement range code
- No indication: 5 V d.c.
A 12 - 24 V d.c.
HEAD OFFICE
Measurement range
 DC voltage
Model
Measurement range Resolving power Input impedance
BA1-ND10-1
199.9 ㎷
BA1-ND10-2
1.999 V
BA1-ND10-3
19.99 V
BA1-ND10-4
199.9 V
※ Accuracy : ±0.2 % of indication value ±1 digit (23 ℃ ±5 ℃)
 DC current
Model
Measurement range Resolving power Input impedance
BA1-ND20-1
199.9 ㎂
BA1-ND20-2
1.999 ㎃
BA1-ND20-3
19.99 ㎃
BA1-ND20-4
199.9 ㎃
BA1-ND20-5
1.999 A
BA1-ND20-6
19.99 A
BA1-ND20-7
199.9 A
BA1-ND20-8
1999 A
※ Accuracy : ±0.2 % of indication value ±1 digit (23 ℃ ±5 ℃)
 DC voltage
Model
Input
BA1-ND11-1
BA1-ND11-2
1 - 5 V DC
BA1-ND11-3
※ Accuracy : ±0.2 % of indication value ±1 digit (23 ℃ ±5 ℃)
 DC current
Model
Input
BA1-ND21-1
BA1-ND21-2
4 - 20 ㎃ DC
BA1-ND21-3
※ Accuracy : ±0.2 % of indication value ±1 digit (23 ℃ ±5 ℃)
Specification
Power supply voltage
5 V d.c.
Power consumption
Approx. 3 W
min
Insulation resistance
10 ㏁
( 500 V d.c.)
Dielectric strenght
1,500 V AC for
Power supply terminal normal mode ± 200 V
Noise resistance
Power supply terminal common mode ± 500 V
Vibration durability
10 - 55 ㎐ Peak amplitude for 2 hours each in X, Y, Z directions
Shock durability
300 ㎨ (Approx 30 G)
Ambient temperature
0 ~ 50 ℃
Ambient humidity
35 ~ 85 % RH
Storage temperature
-10 ~ 70 ℃
MF0204KE230407
HANYOUNGNUX CO.,LTD
28, Gilpa-ro 71beon-gil, Michuhol-gu, Incheon, Korea
TEL : +82-32-876-4697
http://www.hanyoungnux.com
Max allowable input
100 ㎶
100 ㏀
1 ㎷
1 ㏁
10 ㎷
1 ㏁
100 ㎷
10 ㏁
Max allowable input
0.1 ㎂
1 ㏀
1 ㎂
100 Ω
10 ㎂
10 Ω
100 ㎂
1 Ω
1 ㎃
10 ㎃
Use shunt
(secondary voltage 50 ㎷)
100 ㎃
1 A
Max allowable input
Display range
Input impedance
50.0
100 ㏀
100.0
100 ㏀
199.9
100 ㏀
Max allowable input
Display range
Input impedance
50.0
25 Ω
100.0
50 Ω
199.9
100 Ω
12 - 24 V d.c.
Approx. 5 W
1 min (power terminal - input terminal)
voltage
70 V
100 V
250 V
300 V
current
1 ㎃
50 ㎃
150 ㎃
300 ㎃
voltage
100 V
100 V
100 V
current
150 ㎃
150 ㎃
150 ㎃

Advertisement

loading

Summary of Contents for HANYOUNG NUX BA1

  • Page 1 Please check whether the product is the exactly same as you ordered. Before using the product, please read this instruction manual carefully. 28, Gilpa-ro 71beon-gil, Michuhol-gu, Incheon, Korea HEAD OFFICE TEL : +82-32-876-4697 Please keep this manual where you can view at any time http://www.hanyoungnux.com Measurement range Safety information  DC voltage Before using the product, please read the safety information thoroughly and use it properly.Alerts declared in the manual are classified to Danger, Warning and Caution by their criticality Max allowable input Model Measurement range Resolving power Input impedance DANGER indicates an imminently hazardous situation voltage DANGER which, if not avoided, will result in death or serious injury BA1-ND10-1 199.9 ㎷ 100 ㎶ 100 ㏀ 70 V WARNING indicates a potentially hazardous situation BA1-ND10-2 1.999 V 1 ㎷ 1 ㏁ 100 V WARNING which, if not avoided, could result in death or serious injury BA1-ND10-3 19.99 V 10 ㎷ 1 ㏁ 250 V...
  • Page 2 ● W hen turning on 1.999 decimal point, please connect to terminal number Connection diagram 7 (COM) and number 4 terminal which are common terminals of decimal point. Repair and inspection • P lease keep the device under the 60% humidity within the temperature -10 to +70. Please get rid of the dust when using it in the dusty places. DC signal input ( The machine's life is shortened due to high temperature of components in the device). • P lease be cautious not to touch thinner and volatile oil since this instrument's case is molded plastic. ※ When using more than one BA1, please use separate power supply. Please be cautious that ② and ⑧ terminals are internally short. After Service  Power supply connection •Connect power to the power terminal. This product is released out after production, testing, and examination • C onnect "+" to number 1 terminal and "-" to number 2 terminal for power through a strict quality control. If it has broken down, please contact the 5 V d.c. Use the power within ±5 % of 5 V d.c. dealer or our headquarters directly.(Please send the defective product with • E ven using the prevention device against noise depending on the types, the detailed information about it.) it is very difficult to equip the absolute prevention device to such a small...

This manual is also suitable for:

Ba1-nd10-1Ba1-nd10-2Ba1-nd10-3Ba1-nd10-4Ba1-nd20-1Ba1-nd20-2 ... Show all