6. Refrigeration and Water Cycle Diagram

Expansion
Valve
Strainer
Strainer
Expansion
Defrost
Valve
Sensor
(Bypass)
Pipe
Temp.
Sensor
Air
Temp.
Sensor
Heat
Exchanger
Low
Pressure
Sensor
High
Pressure
Sensor
Compressor
Discharge
Temp. Sensor
Compressor
Refrigerant Cycle
Water Cycle
Mono bloc Unit
Strainer
Subcooler
Strainer
Bypass
Exit
Temp.
Sensor
Eva
Exit
Temp.
Sensor
4-Way
Valve
Pressure
Switch
Muffler
Compressor Tank
Temp. Sensor
Expansion
Liquid
Vessel
Side
(2-Way
Valve)
Pipe
Temp.
Sensor
Exchanger
Drain
Backup Heater
Gas
Side
(3-Way
Valve)
21
Outdoor
Side
Water
Pressure
Gauge
Water
Capillary
Flow
Tube
Switch
Water
Pump
Pipe
Temp.
Sensor
Heat
Air Purge Valve
Pressure
Relief
Valve
Pipe
Temp.
Sensor
Water
Inlet
(Connect
to
Sanitary
Tank)
Water
Outlet
(Connect
to
Sanitary
Tank)