Panasonic WH-MHF12G9E8 Service Manual page 14

(mono bloc) air-to-water heat pump system
Hide thumbs Also See for WH-MHF12G9E8:
Table of Contents

Advertisement

Operation/settings to be done only by the authorised dealer/specialist.
Dealer
Operation/settings to be done by the authorised dealer/specialist or user.
User
9
Booster Heater
To activate or deactivate the water tank's booster heater.
Note: If NO is selected, menu 10 is skipped.
10
Booster Heater Delay Timer
To delay time for the booster heater to activate while the system is
heating up the water tank.
• Do not use the system during sterilisation in order to prevent scalding with hot water, or overheating of shower.
• Ask an authorised dealer to determine the level of sterilisation function field settings according to the local laws and
regulations.
11
Sterilisation
To sterilise the water tank, if required.
Note: If NO is selected, menus 12 to 14 are skipped.
12
Sterilisation Day & Time
To set timer for sterilisation.
(Only once a week. Operates even under a standby condition)
13
Sterilisation Temperature
To set the temperature of sterilisation.
14
Continuation of Sterilisation
To maintain heating temperature in order to complete the
sterilisation.
15
Base Pan Heater
To select whether or not to connect to the optional base pan
heater.
Note: If NO is selected, menu 16 is skipped.
16
Base Pan Heater type
Type A - The base pan heater activates only during deice
operation.
Type B - The base pan heater activates when outdoor ambient
temperature is 5 °C or lower.
17
Dry Concrete
During construction to dry the concrete under a preset
temperature.
Do not use this menu for any other purposes and in period other
than during construction (Refer to information page).
User
Remote control preparation
1 Press
.
2 Press
or
to set the current day.
3 Press
to confirm.
4
Repeat steps
2
and
Note:
The current day and time need to be set in cases below:
- When the power is turned on for the first time.
- A long time has elapsed since the power was turned on the
last time.
• The current time that has been set will be the standard time for
all the timer operations.
3
to set the current time.
14
YES
YES
20 minutes ~
1 hour
1 hour 35 minutes
YES
YES
Monday
Monday ~ Sunday
12:00
0:00 ~ 23:50
70 °C
40 °C ~ 75 °C
5 minutes ~
10 minutes
1 hour
NO
YES
A
A
-
1 day ~ 99 days
Caution Indicator (Tank Temperature above 60 °C)
NO
NO
NO
B