G022P has two digital input ports which can be used to monitor external signals. These two external input
ports can accept 0 V to 24 V voltage levels. Should the input voltage level be below 1.0 V, the main mobile
terminal will receive the warning message „Port n has been triggered‟, where n is the relay number. The
relay n will switch to the normal state (NC will be the closed state and NO will be the open state). Sending
„EXTRT‟ will release the relays and make them available for responding to SMS commands.
https://www.quark-elec.com
V2
Monitoring/alarm input
EXTRT
EXTGBn
n=1, Relay 1
n=2, Relay 2
n=3,
only
available
PIRwireless PIR detector
(G022P variant)
25 of 30
Note: The local time will not be affected by
switching off the timer.
After it has been triggered by the external
signals, the related relay will be locked in the
normal state. By sending „EXTRT‟, the relays
will be unlocked and available for responding to
SMS commands again.
By sending „EXTGBn‟, the external alarm input
n will be disabled. Message „Alarm input n has
been disabled.‟ will be returned to the operator
if the setting is successful, where n is „1‟
for
„2‟or‟3‟.
By sending „EXTRT‟ all external alarm inputs
will be active.
This disable status isn‟t achievable by re-
powering up the module, only „EXTRT‟ will re-
enable the external alarm input.