Quark-Elec QK-G022P Manual page 24

Gsm remote controller
Table of Contents

Advertisement

Quark-elec Manual
Check
relay
working
mode
Check relay working
status
One-off
relay
switch
toggling
Set time on 021/022
Check the local time on
021/022
Set Switching Relays ON
time
Set
Switching
Relays
OFF time
Check the current setting
of the timer
Switch
off
the
Timer
setting
https://www.quark-elec.com
V2
RMODE
WHOACTIVE
ONOFFRnxxx#
n=1, Relay 1; n=2, Relay 2.
xx range from 001 to 999,
indicating the delay time in
seconds.
*From
Aug
2018,
command has changed to
be „ONOFFRnxxx#‟; this
allows the maximum time
can be 999 seconds.
Timer
SThhmmss#
Where
hhmmss
is
current time
DQSJ
ONnhhmmss
n=1, Relay 1
n=2, Relay 2
hhmmss is the Switch ON
time.
OFnhhmmss
n=1, Relay 1
n=2, Relay 2
hhmmss is the Switch OFF
time.
RELAYnTIMER
n=1, Relay 1
n=2, Relay 2
GDSn
n=1, Relay 1
n=2, Relay 2
24 of 30
Where n is the relay number.
G022P will reply with the relay working mode
information in the following format:
„MMMM1MMMM2‟, where MMMM could be
INCH or SELF.
control mode (relay will act for 3 seconds and
then revert to the normal position), and SELF
refers to Self-lock mode.
For example, INCH1SELF2 means, relay 1
works in Latching control mode and relay 2
works in Self-lock mode.
G022P will reply with the relay working status
information similar to the following
format:
„R1, R2, R3: ACTIVE; DEACTIVE; ACTIVE.‟
Where ACTIVE means the related relay has
been triggered (COM port connected to NO
port),
DEACTIVE means the related relay is on the
normal status.
For example, by receiving ONOFFR175#, the
first relay (Relay 1) will be triggered on for 75
seconds and then switched off, whether G022P
is working in Latching mode or in Self-lock
mode. G022P will reply with the relay
this
information in the following format:
„Port 1 is ON and will be OFF 75 seconds
afterwards„.
This is a one-off command, only valid for one
time action. The APP does not support this
command, so the operator should use SMS to
send this message.
For example, by sending ‟ST153000#‟, the
the
operator set G022P time as 15:30:00. G022P
will
return
the
successful‟ to accept this setting. If the
operator sends the wrong time format, G022P
will return the message ‟Time setup failed‟.
By sending „DQSJ‟, the operator will receive
the local time. The message received would be
„Time at terminal is 12:30:32‟.
For example, by sending „ON2163000‟, the
operator set Switch Relay 2 ON at 16:30:00.
Message as „Port 2 will switch ON‟ will be
returned to operator if the setting successful.
For example, by sending „OF2194500‟, the
operator set Switch Relay 2 OFF at 19:45:00.
Message as „Port 2 will switch OFF‟ will be
reply to operator if the setting successful.
For example, by sending "RELAY2TIMER",
the timer setting on reply 2 will be reply to
operator. The replied message will be similar
as ‟Port 2 will switch ON at 12:30;00 and
switch OFF at 13:30:00‟
Message „Timer on Relay n has switched OFF‟
will be returned to the operator if the setting is
successful; where n is „1‟ or ‟2‟.
INCH refers to Latching
message
„Time
setup
2018

Advertisement

Table of Contents
loading

This manual is also suitable for:

G021G022G022pG022gG033

Table of Contents