(241IO) SALTWATER SYSTEM & SAND FILTER PUMP (14" & 16") ENGLISH 7.5" X 10.3" PANTONE 295U 08/09/2013
ELECTROLYTIC CELL CLEANING
If the pool water is hard (high mineral content) the cell may require periodic manual cleaning. To
maintain maximum performance, we recommend that you open and visually inspect the
electrolytic cell (22) once every month.
The following steps are some instructions on how to clean your cell.
1. Switch off the unit, unplug the power cord from the electrical socket.
2. Disconnect the hose (12) from the electrolytic cell (22) outlet and cover the outlet with the
drain outlet cover (3) from the 6-way valve (see drawings 36 and 37).
3. Remove the electrolytic cell from the 6-way valve outlet by unscrewing the electrolytic cell (22)
collar (see drawing 38).
4. Pour kitchen grade vinegar into the cell to immerse the titanium plates (see drawing 39).
Soak for about 1 hour and then flush with a high-pressure garden hose.
5. Reverse steps 2 to 4 to reconnect the electrolytic cell.
36
COPPER ELECTRODE CLEANING
1. Switch off the unit, unplug the power cord from the electrical socket.
2. In a counter-clockwise motion, unscrew the electrical plug collar from the copper electrode
cell, and remove the electrical plug from electrode cell (see drawings 40 and 41).
3. Unscrew the copper electrode cell collar, then remove the electrode cell and place it on a
bucket.
4. Pour kitchen grade vinegar into the bucket until the copper electrode cell is immersed (see
drawing 43). Soak for 1 hour and then flush with a high-pressure garden hose.
5. Reverse steps 2 to 4 to reconnect the copper electrode cell.
40
24
SAVE THESE INSTRUCTIONS
38
37
22
3
22
42
41
English
241A
39
43